THIS SYSTEM IS CAPABLE OF
PRODUCING 1600 PSI TO AVOID
RUPTURE AND INJURY, DO NOT
OPERATE THIS PUMP WITH COM-
PONENTS RATED LESS THAN 1600
PSI WORKING PRESSURE (IN-
CLUDING BUT NOT LIMITED TO
SPRAY GUNS, HOSE AND HOSE
CONNECTIONS).
BEFORE SERVICING, CLEANING
OR REMOVING ANY PARTS, SHUT
OFF POWER AND RELIEVE PRES-
SURE.
protection from the risk of electric
shock. Should replacement of the plug
or cord become necessary, use only
identical replacement parts that include
GFCI protection.
WATER SUPPLY
(Cold Water Only)
ƽ CAUTION
When connecting the water inlet to the
water supply mains, local regulations of
your water company must be observed.
In some areas the unit must not be con-
nected directly to the public drinking wa-
ter supply. This is to ensure that there is
no feedback of chemicals into the water
supply. Direct connection via a receiver
tank or backflow preventer, for example,
is permitted.
IF CONNECTION IS MADE TO A PO-
TABLE WATER SYSTEM, THE SYS-
TEM SHALL BE PROTECTED
AGAINST BACKFLOW.
SERVICING OF A DOUBLE-
INSULATED PRODUCT
Dirt in the feed water will damage the
unit. To avoid this risk, we recommend
fitting a water filter.
Garden hose must be at least 1/2
inch or 5/8 inch in diameter.
Flow rate of water supply must not
fall below 2 GPM (gallons per
minute).
Flow rate can be determined by run-
ning the water for one minute into an
empty 5-gallon container.
The water supply temperature must
not exceed 104°F/40°C.
Never use the pressure washer to
draw in water contaminated with sol-
vents, e.g. paint thinners, gasoline,
oil, etc.
In a double-insulated product, two sys-
tems of insulation are provided instead
of grounding. No grounding means is
provided on a double-insulated product,
nor should a means for grounding be
added to the product. Servicing a dou-
ble-insulated product requires extreme
care and knowledge of the system, and
should be done only by qualified service
personnel. Replacement parts for a
double-insulated product must be iden-
tical to the parts they replace. A double-
insulated product is marked with the
words “DOUBLE INSULATION” or
“DOUBLE INSULATED”. The symbol
“
” may also be marked on the product.
Always prevent debris from being
drawn into the unit by using a clean
water source.
GROUND FAULT CIRCUIT
INTERRUPTER PROTECTION
This pressure washer is provided with a
ground-fault circuit-interrupter (GFCI)
built into the plug of the power-supply
cord. This device provides additional
SAVE THESE INSTRUCTIONS!
English 5
Categories | Kärcher Pressure Washer Manuals, Pressure Washer Manuals |
---|---|
Tags | Kärcher K 2.28 |
Download File |
|
Language | English, Français, Español |
Product Brand | Kärcher. Kärcher US Home and garden support phone: 1-800-537-4129 Kärcher international support: http://www.karcher.com/start/choose_your_language.htm, Pressure Washer |
Document File Type | |
Publisher | karcherresidential.com |
Wikipedia's Page | Kärcher |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)