English
The following intervals apply to normal operating conditions only. If your daily work-
ing time is longer or operating conditions are difficult (very dusty work area, resin-
rich wood, tropical wood, etc.), shorten the specified intervals accordingly. If you only
use the saw occasionally, extend the intervals accordingly.
Cooling inlets
Clean
Clean
Clean
Clean
X
X
X
Air inlet on fan housing
Cylinder fins
X
X
X
X
X
X
Preseparator port and carburetor body
"Carb preheat" shutter and preheating port Clean (winter operation only)
Check idle adjustment – chain must not
rotate
X
X
Carburetor
Spark plug
Readjust idle
X
X
Readjust electrode gap
Replace after every 100 operating hours
X
X
All accessible screws and nuts (not adjust-
ing screws) 3)
Retighten
Check
Spark arresting screen in muffler
Combustion chamber
Clean or replace
X
Decoke after first 139 hours of operat-
ing, then every 150 hours
X
Check
X
Chain catcher
Safety labels
Replace
Replace
X
X
1)
2)
3)
STIHL recommends a STIHL servicing dealer.
see chapter on "Chain Brake"
Firmly tighten down the cylinder base screws of professional saws (3.4 kW or more) after 10 to 20 hours of operation.
5
2
MS 261 C-Q
Categories | Chainsaw Manuals, STIHL Chainsaw Manuals |
---|---|
Tags | STIHL MS 261 |
Download File |
|
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Chainsaw |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(1 votes, average: 5 out of 5) Lawn and Garden readers have rated STIHL MS 261C Q Chainsaw Owners Manual 5.0 out of 5.0 based on 1 product reviews.
Just bought this saw and it’s great so far