STIHL SE 122 Wet Dry Vacuums Owner Manual

English
Fault: No suction performance when
wet-vacuuming
Troubleshooting
Cause
Remedy
Fault: Motor does not start
Container full
(intake port is
sealed by float)
See "Emptying the
container"
Cause
Remedy
Mains circuit-
Check and reset
breaker has been     mains circuit
tripped
breaker
Overload protection Let vacuum
has been tripped
cleaner cool for
approx. 5 minutes
Fault: Poor suction performance
Cause
Remedy
Filter bag is full
See "Emptying the
container"
Suction hose / tool   Clean suction
is clogged
hose / tool
Filter element is
fouled
See "Cleaning the
filter element" and
"Replacing the fil-
ter element"
Gasket between
upper part of vac-
uum cleaner and
container is fouled
or faulty
Clean or replace
gasket