Toro EZFlo Plus Globe Angle Installation Catalog

EZ-Flo  Plus 1" (25 mm) Globe and Angle Valve Series
TM
Installation and Operating Instructions
Specifications
Flow range: 0.25 – 30 GPM (1,0  – 114 LPM)
Operating pressure: 10 – 150 PSI   (0,70 – 10 Bar)
Encapsulated Solenoid:
24
19
V a.c., 50/60 Hz (nominal)
V a.c., 50/60 Hz (minimum)
Inrush: 0.40 amps, 9.6 VA @ 24 V a.c., 60  Hz
0.34
amps, 8.16 VA @ 24 V a.c., 50 Hz
Holding: 0.20 amps, 4.8 VA @ 24 V a.c.,  50/60 Hz
Friction Loss:
GPM Flow   0.25
5
3.5
3.3
10
4.0
2.2
15
3.0
1.8
20
3.3
1.9
30
6.2
3.9
PSI Loss
2.0
2.0
(Globe)
(Angle)
LPM Flow
1
19
38
57
76
114
Bar Loss    0,138   0,241
0,276
0,207   0,228  0,427  (Globe)
0,124   0,131  0,269  (Angle)
0,138
0,228   0,152
Valve Installation Guidelines
This valve series does not provide backflow  prevention. Contact your local municipal authority for specific building codes,  permits
and backflow prevention measures required for the  connection of an underground sprinkler system.
Note the flow direction arrows on the  side of the valve body and install accordingly.
The valve may be installed at any  angle when operating in a clean water system. In effluent  water systems, the valve must only be
installed with the solenoid in the upright  vertical position.
When installing valves below grade, installation within  a valve box is recommended for protection, ease of adjustment  and service.
Installing a manual shut-off valve between the  main water supply and automatic valve or valve manifold is  recommended for ease of
valve maintenance and sprinkler system winterization.
Installation Procedure
Figure 1
Female Threaded Valve Body
Female Slip Valve Body
Male Thread/Barb Valve Body
Male Threaded Valve Body
Angle Valve Body
Valve Box
Slip/Male Thread Adapters
Pipe Cemented to Body
Hose Clamp
Poly Pipe
Slip/Female Thread Adapters
Slip/Male Thread Adapters
1.
2.
From the backflow device, route (25 mm)  1" schedule 40 PVC pipe to the valve or valve  manifold inlet. Use 25 mm (1") class 200
PVC on the valve outlet. Valves with  a barbed outlet require a 1" (25 mm) or 1.25"  (32 mm) polyethylene (poly) pipe.
For threaded valve body models, prepare 1"  (25 mm) slip/thread PVC pipe adapter fittings with three to  five complete wraps of
Teflon®tape evenly  covering the threads. Install adapters to the valve body and  tighten securely.
CAUTION: Use only Teflon tape on threaded valve connections. Pipe dope or similar compounds will damage plastic threads.
Flush the supply line thoroughly before installing  the valve.
3.
4.
Carefully prime and cement PVC pipe to  the valve fittings (or directly to valve for slip-fit valve  models).
CAUTION: Apply PVC cement sparingly. Excess cement can pool in the valve body and damage the internal bleed port.
Note: Allow all cemented PVC fittings to cure for  at least one hour before applying water pressure.
On barbed outlet valve, slip a stainless  steel hose clamp onto the poly pipe. Push the
5.
6.
7.
Figure 2
poly pipe onto the barbed fitting covering  all barbs. Position the hose clamp over the
barb contact area and tighten securely.
Wire Connector
Valve Common
White Wire
Sprinkler Cable
From Timer
Route a multi-wire, direct-burial sprinkler cable from the sprinkler timer to the valve.
2
If the cable run is less than 800' (244 m), 18 AWG (1.0 mm ) wire is sufficient. For
2
distance from 800' 2000' (244 m 610 m), 14 AWG (2.5 mm ) wire is recommended.
Using wire splice connectors, attach either wire  from each valve solenoid to the white
cable wire. This wire is designated as  the valve common wire. Connect the remaining
wire from the solenoid to one of  the color-coded cable wires. Ensure all wire connec-
tions are secure and waterproof.
Grease Cap
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 2 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website