Toro Thero Promise Irrigation Owners Manual

Installing the Pump Starter
Connecting the Pump Starter
Mount the Pump Starter
A.  Assemble conduit piping and connect wiring  from the electrical junction box
(power source) to one set of the  Pump Starter’s yellow / blue power wire
pairs.  Attach wires by using insulated wire  connectors as shown in the
illustration.
A. Assemble the hanger to the back of the case using the
screw provided.
B. Remove the wiring cover and remove the screw from
the voltage plate marked “Caution: High Voltage”.
B.  Assemble conduit piping, and connect wiring from the pump to the remaining
Pump Starter’s yellow / blue power  wire pairs.
C. Mount the Pump Starter on a wall or solid surface
using the hanger.  Secure by installing screws through
the two holes located in the lower wiring compartment.
C.  Carefully arrange all wiring connections in the wiring cavity  making sure that
there are no exposed or loose connections.   Replace the “Caution: High
Voltage” plate.
CAUTION: When installing with an electronic timer:
The Automatic Pump Starter should be mounted at
CAUTION: The Pump Starter is designed to control up  to a 2 HP
(at 250 V a.c.) motor only.   (Note:  2 HP at 120 V a.c. will exceed  the
maximum AMP rating.)  Do not attach to larger  commercial units, or exceed the
contact ratings as listed below.
(1)
least 5 feet away from the timer.  (2) The timer should be
at least 12 feet away from the pump.  (3) The pump
should be on a separate power source than that of the
timer (the pump  is a high power user).  If these steps are
not taken, timer malfunctions may occur.
Connect Pump Starter to the sprinkler timer:
The remaining two white wires are connected to your sprinkler timer. Make sure
the timer does not exceed 30 V a.c. output. It is not necessary to run conduit
piping from the white relay wires to your timer, since the same low voltage that
controls the sprinkler valves will also control the relay.
Connect Pump Starter to power source
and pump motor:
Note: Use 18-gauge wire for runs up
to 800'. For longer distances (2000'
maximum), use 14-gauge wire.
PUMP
COMMON
TIMER TERMINAL
STRIP
WARNING:  To prevent danger of electrical shock,
turn off main circuit breaker switch before making
any electrical connections.
A.  Run a single wire from your timer’s
“common” terminal to either either
one of the white wires in the wiring
compartment.
YELLOW / BLUE
WIRE PAIR TO
PUMP STARTER
YELLOW / BLUE
WIRE PAIR TO
PUMP STARTER
B.  Run a single wire from your timer
“Pump” or “Master Valve” terminal
to the other white wire.
YELLOW / BLUE
WIRE PAIR TO
POWER SOURCE
PUMP STARTER
SWITCHING RELAY
WHITE WIRE
PAIR TO TIMER
C.  Connect the wires using insulated
wire connectors.
YELLOW / BLUE
WIRE PAIR TO
POWER SOURCE
RELAY RATINGS:
Contacts rated:
PUMP
D.  Install the wiring cover.
1HP at 120 V a.c. 1 Phase
2HP at 250 V a.c. 1 Phase
20A at 250 V a.c.
PUMP POWER SOURCE
JUNCTION BOX
When the sprinkler timer activates a
control valve, it will simultaneously
send voltage to the Pump Starter’s
coil/switch, and turn on the pump
motor.
Coil rating:
24
V a.c., 3 VA
Operating Req:
Min. 19 V a.c.
Max. 30 V a.c.
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 2 pages
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website