B   Controllers with no sensor inputs and no pump start  or master valve:
Irrigation System  Controller
PUMP/
MV
1
2
3
4
COM
24 VAC
To Valves
Brown
Common Wire  From Valves
Wire Connector
White
Yellow- Not Used
Remove the valve common wire from the  valve common terminal (generally marked
“C”, “COM”, or “VC”). Join this wire  to the White wire using a wire connector. Attach
the Brown wire to the valve common  terminal.
Note: The yellow wire is not used in  this application.
C   Controllers with pump start or master valve and no  sensor inputs:
Irrigation System  Controller
PUMP/
MV
1
2
3
4
COM
24 VAC
To Valves
Brown
Pump Start
Relay/Master
Valve
Yellow - Not Used
White
Common Wire  From Valves
Wire Connector
Remove all common control wires from the valve common terminal(s) of the controller
(generally marked “C”, “COM”, or “VC”). Join these wires to the White wire using a wire
connector. (Be sure to include the common wire from the pump start relay or master
valve in this connection). Attach the Brown wire to the valve common terminal.
Note: The yellow wire is not used in  this application.
5
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 12 pages
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website