MAINTENANCE
Air filter
Changing a broken recoil spring
•
•
Lift off the pulley. See instructions under heading
Changing a broken or worn starter cord.
The air filter must be regularly cleaned to remove dust and
dirt in order to avoid:
Remove the recoil spring from inside the pulley by
tapping the pulley lightly with its inside face
downwards against a work bench or the like. If the
spring pops out during fitting, wind it up again, working
from the outside in towards centre.
•
•
•
•
•
Carburettor malfunctions
Starting problems
Loss of engine power
Unnecessary wear to engine parts.
Excessive fuel consumption.
•
Lubricate the recoil spring with light oil. Fit the pulley
and tension the recoil spring.
•
Remove the air filter after taking off the air filter cover.
When refitting make sure that the air filter seals tightly
against the filter holder. Clean the filter by brushing or
shaking it.
Fitting the starter
•
To fit the starter, first pull out the starter cord and place
the starter in position against the crankcase. Then
slowly release the starter cord so that the pulley
engages with the pawls.
•
Fit and tighten the screws that hold the starter.
The filter can be cleaned more thoroughly by washing it in
water and detergent.
An air filter that has been in use for a long time cannot be
cleaned completely.The filter must therefore be replaced
with a new one at regular intervals. A damaged air filter
must always be replaced.
A HUSQVARNA chain saw can be equipped with different
types of air filter according to working conditions, weather,
season, etc. Contact your dealer for advice.
English – 33
Categories | Chainsaw Manuals, Husqvarna Chainsaw Manuals |
---|---|
Tags | Husqvarna 576XP |
Model Year | 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009 |
Download File |
|
Document Type | Operator's Manual |
Language | English |
Product Brand | Husqvarna, Chainsaw |
Document File Type | |
Publisher | husqvarna.com |
Wikipedia's Page | Husqvarna |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)