SECTION 6 - AUGER AND DISCHARGE CHUTE
6.1
AUGER
6.2 DISCHARGE CHUTE DEFLECTOR
The auger consists of two halves bolted together over
the auger shaft.
(938001, 938003, 938006-938009, 938301,
938303)
To replace the auger:
If chute deflector does not stay in set position, tighten
fasteners evenly until deflector stays in position
(Figure 8). Use a #T30 Torx drive or a 3/16" (.19 cm)
wide straight screwdriver to tighten.
1.
2.
3.
Unscrew the twelve self tapping screws.
Remove one half.
Rotate second half out.
938002, 938004, 938302
NOTE: The screws tap into a metal plate. Save these
for reassembly.
Adjust chute deflector control lever pivot bolt nut until
the control stays in position. (Figure 9).
Check roll pins in auger shaft and replace as needed.
Assemble in reverse order.
When the chute deflector hits its stop for maximum
down deflection, the chute deflector control lever
should hit its stop on housing at the same time.
Lock in position by adjusting and tightening nuts
against bracket. (Figure 9)
Discharge chute may freeze in extreme cold conditions
and not rotate freely. To correct for this condition the
discharge chute handle assembly will need to be
removed from the gear discharge chute segment. The
pocket in the handle assembly for the spring and ball
detent will need to be packed with grease. The metal
ring in which the discharge chute is trapped will need a
liberal coat of grease as well.
1
3
2
3
4
1.
2.
Discharge Chute
Rotation Bracket
Self-Tapping Bolt Plate
3. Half Auger
4. Auger Shaft
Figure 8
PS0063
Figure 9
6
- 15
Categories | Ariens Snow Blower Manuals, Snow Blower Manuals |
---|---|
Tags | Ariens 938001, Ariens 938004, Ariens 938006, Ariens 938012, Ariens 938015, Ariens 938016, Ariens 938301, Ariens 938305 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Ariens, Snow Blower |
Document File Type | |
Publisher | ariens.com |
Wikipedia's Page | Ariens |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)