English / USA
Metering Unit
Step 4:
Step 5:
Determine walking speed
Determine discharge rate
Carry out a trial run with the machine
fueled and the container filled with water.
Operate the spray tube (swing it back
and forth) as it will be during the real run
described below. Determine the
The setting of the metering knob is
calculated as follows:
V (l) x v (m/min) x b(m)
a
b
A (m )
––––––––––––––––––––––
= Vc (l/min)
distance walked in one minute.
2
Also use the trial run to check the
selected working width. In the case of
low-growing crops, the best working
width is 4-5 m. The working width should
be marked with stakes.
Va = Quantity of solution
vb = Walking speed
Vc = Discharge rate
Dividing the distance in meters by the
time in minutes gives you the walking
speed in meters per minute (m/min).
b
= Working width
A
= Area
Example:
Example:
:
:
:
The stop cock (1) is closed when the
The distance covered in one minute is
The values determined in Steps 1-4 and
a working width of 4 m produce the
following discharge rate (setting of
metering knob):
lever is upright.
10
meters.
The stop cock (1) is open when the
Walking speed:
lever is parallel to the hose.
10
m
Adjust the discharge rate with the
144
l x 10 (m/min) x 4 m = 1.6 l/min
–––––
= 10 m/min
metering knob – not the stop cock.
––––––––––––––––––––
1
min
2
m
3,600
Hectares (ha) have to be converted into
2
2
m (ha x 10,000 = m ).
SR 340, SR 420
23
Categories | Backpack Sprayer Manuals, Blower Vacuum and Sweeper Manuals, STIHL Backpack Sprayer Manuals, STIHL Blower and Vacuum Manuals |
---|---|
Tags | STIHL SR 340, STIHL SR 420 |
Download File |
|
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Blower Vacuum |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)