3.
Route the control and common wires into the controller cabinet
through the 2" (52mm) access opening. Remove approximately
1/2"
(13mm) insulation from the ends of each wire.
4.
5.
Attach the field common wire to one of the three valve common
terminals labeled VC/COM.
Referring to Figure 5, connect each valve control wire to the
appropriate station number terminal. If an optional master valve
is installed, connect its control wire to the terminal labeled
MV/PUMP. Tighten all terminal screws securely.
Figure 5
Pump Start
Relay
Valve Station 3
or
Master Valve
Valve Station 2
Valve Station 1
Valve Common
CONNECTING A PUMP START RELAY
When a pump is to be operated by the controller, a compatible relay
must be used. The relay coil will be connected to the master
valve/pump (MV/PUMP)terminal and must be rated for 24 V a.c. at
0.5A
maximum. The relay contacts will be connected to the pump
start terminals and must be rated for use with the particular pump.
Note: Transient suppressors may be needed across the relay contacts
in installations using large pumps.
Caution: To prevent controller damage, do not connect the
master valve output terminal directly to the pump start
terminals.
Installation Procedures
21
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document Type | Owner's Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)