Connecting the Receiver Wires
CAUTION: The receiver requires continuous 24 Vac power for operation. Connecting to
higher power will result in irreparable damage. Ensure that power to the controller has
been removed prior to connecting the receiver wires.
The sensor system is designed to work with most makes and models of irrigation controllers.
•
•
If your controller is equipped for a sensor connection, follow the steps in Wiring Procedure I.
If your controller is not equipped for a sensor connection, use Wiring Procedure II on page 7.
Wiring Procedure I (sensor-ready)
Note: Refer to your controller user’s guide
to determine the type of sensor required:
Normally Closed (NC) or Normally Open (NO).
Figure 2 - Normally-closed Sensor
Jumper
TWRFS-I
1.
Locate the sensor connection terminals,
usually labeled “SENSOR” or “SN.”
Remove the jumper connector (if installed).
PUMP/
MV
SENSOR
COM
24 VAC
1
2
3
4
2.
3.
Attach the White wire to either Sensor
terminal (disregard +/ – polarity if labeled).
Red
For a Normally-Closed sensor type , attach the
Brown wire to the remaining Sensor terminal.
Tape back the Yellow wire. See Figure 2.
To Valves
Red
White
Brown
X Yellow
6
Categories | Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro TWRS Series |
Download File |
|
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939 |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)