English / USA
Lubricating the
Gearbox
If engine is down on power, difficult to
start or runs poorly at idling speed, first
check the spark plug.
1
:
Remove spark plug as described
in chapter "Starting / Stopping the
Engine".
2
2
:
:
Clean dirty spark plug.
Check the electrode gap (A) and
readjust if necessary – see
"Specifications".
:
Check grease level regularly - about
every 25 hours of operation.
:
Use only resistor type spark plugs
of the approved range.
1
:
:
Unscrew the filler plug (1).
Rectify problems which have caused
fouling of spark plug:
If no grease can be seen on the
inside of the filler plug, screw the
tube (2) of STIHL gear lubricant for
brushcutters - see “Special
:
:
:
Too much oil in fuel mix.
Dirty air filter.
Accessories” - into the filler hole.
Unfavorable running conditions,
e.g. operating at part load.
:
:
Squeeze up to 1/5 oz (5 g) grease
into the gear housing.
To reduce the risk of fire and burn
injury, use only spark plugs
Fit a new spark plug after approx.
operating hours
Do not completely fill the gear
housing with grease.
100
authorized by STIHL. Always press
spark plug boot (2) snugly onto
terminal (1) of the proper size.
(Note: If terminal has detachable
SAE adapter nut, it must be
or earlier if the electrodes are badly
eroded.
Refit the filler plug and tighten it
down firmly.
attached.) A loose connection
between spark plug boot and
ignition wire connector in the boot
may create arcing that could ignite
combustible fumes and cause a fire.
FS 130, FS 130 R
43
Categories | Blower Vacuum and Sweeper Manuals, STIHL Trimmer Manuals, Trimmer Manuals |
---|---|
Tags | STIHL FS 130 |
Download File |
|
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Trimmer |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)