Maintenance and Care
The following intervals apply to normal operating conditions only. If your daily work-
ing time is longer or operating conditions are difficult (very dusty work area, etc.),
shorten the specified intervals accordingly.
Visual inspection (condition, leaks)
X
X
X
X
Complete machine
Clean
X
Control handle
Check operation
Clean
X
X
X
X
Air filter
Replace
Check1)
X
X
Pickup body in fuel tank
Fuel tank
Replace1)
Clean
X
X
X
X
Check idle adjustment – the cutting
attachment must not turn
X
X
Carburetor
Readjust idle speed
X
Readjust electrode gap
Replace after every 100 operating hours
Visual inspection
X
X
Spark plug
X
Cooling inlets
Clean
X
X
Check1)
Spark Arrestor in Muffler
Combustion chamber
Clean or replace 1)
X
Decoke after first 139 hours of opera-
tion, then every 150 hours of operation
X
All accessible screws and nuts (not adjust-
ing screws)
Retighten
X
X
Check
X
X
Antivibration elements
Replace1)
X