English
Troubleshooting
Always remove the battery before carrying out any work on the power tool.
Condition
Cause
Remedy
No electrical contact between power tool Removebattery, check contacts and refit
and battery
battery
Battery discharged
Charge the battery
(1
light emitting diode on battery flashes
green)
Battery too hot / too cold
Allow battery to cool down / Warm up
battery slowly at a temperature of 60°F
to 70°F (15°C–20°C).
(1
light emitting diode on battery lights
up red)
Battery faulty
Install new battery1)
Machine does not run when switched on
(4
light emitting diodes on battery flash
red)
Power tool too warm
Allow power tool to cool down
Have power tool checked by servicing
(3
light emitting diodes on battery light
up red)
Power tool faulty
1)
dealer
(3
light emitting diodes on battery flash
red)
Moisture in power tool and/or battery
Allow power tool/battery to dry
Battery or power tool circuitry too warm Take the battery out of the power tool;
allow the battery and power tool to cool
down
Power tool cuts out during operation
Electrical malfunction
Remove the battery and refit it properly
HSA 65
23
Categories | Hedge Trimmer Manuals, STIHL Hedge Trimmer Manuals, Trimmer Manuals |
---|---|
Tags | STIHL HSA 65 |
Download File |
|
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Trimmer |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)