English
Always remove the battery before carrying out any work on the power tool.
Condition
Cause
Remedy
Battery is not fully charged
Charge the battery
Check battery1) and replace
Life of battery has been reached or
exceeded
Running time is too short
Blades sticking / dirty
Clean the blades and spray them with
STIHL resin solvent
Battery jams when being inserted in power
tool / charger
Guides dirty
Carefully clean the guides
Battery too hot / too cold
Allow battery to cool down / Warm up
battery slowly at a temperature of 60°F
to 70°F (15°C–20°C).
(1
light emitting diode on battery lights
up red)
Battery is not charging even though the light
emitting diode on the charger lights up green
Operate the charger only in enclosed
and dry rooms at ambient temperatures
between 40°F (5°C) and 105°F (5°C–
40°C).
No electrical contact between charger Remove the battery and refit it properly
and battery
Battery faulty
Install new battery1)
Light emitting diode on charger flashes red
(4
light emitting diodes on battery flash
red for about 5 seconds)
Charger faulty
Have charger checked by servicing
dealer
1)
1)
STIHL recommends a STIHL servicing dealer.
2
4
HSA 65
Categories | Hedge Trimmer Manuals, STIHL Hedge Trimmer Manuals, Trimmer Manuals |
---|---|
Tags | STIHL HSA 65 |
Download File |
|
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Trimmer |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)