STIHL KM 85 Blower Kombi System Owners Manual

english / USA
Replacing the Starter Rope
and Rewind Spring
1
4
5
2
1
1
1
3
To reduce the risk of fire and burn
injury, use only spark plugs
:
:
:
Take out the screws (1).
Remove the cable lug (if fitted).
Lift the starter cover (2) away from
the tank (3) and pull it out from
under the shroud (4).
:
:
Take out the screw (5).
Remove the rope rotor very
carefully – the rewind spring is
seated in the rope rotor and may
pop out and uncoil if care is not
taken.
authorized by STIHL. Always press
spark plug boot (2) snugly onto
terminal (1) of the proper size.
(Note: If boot has detachable SAE
adapter nut, it must be attached.)
A loose connection between spark
plug boot and ignition wire
connector in the boot may create
arcing that could ignite combustible
fumes and cause a fire.
24
KM 85, KM 85 R
Product Specification
CategoriesMulti-Task Kombi Equipment Manuals, Stihl Kombi Equipment Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 72 pages
LanguageEnglish, Español
Product BrandSTIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Blower Vacuum
Document File TypePDF
Publisherstihl.com
Wikipedia's PageStihl
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website