Toro Automatic Sprinkler System Control Timer Irrigation Owners Manual

Pump Control
2
The Special Functions dial position provides optional
control features specifically for pump system operation.
Pump/Master Valve control circuit operation is active
(On) with two seconds of delay time (turns on two sec-
onds before the first zone begins watering) but can be
turned Off for each watering program as needed.
The pump delay time can be adjusted from 1 to 60
seconds.
5
3
6
5
6
1
4
Turn the control dial to the SPECIAL  FUNCTIONS
position.
Check the PROGRAMS switch setting. If necessary,
reposition the switch to select the desired program.
3.
The display will show P On (Pump On) and will
begin flashing.
To turn the pump circuit Off for this program, press
the –/OFF button; POFF will be displayed.
Press the NEXT button to display the pump delay
time. Pd 02 will be displayed. (A two-second pump
delay is set by default for each program).
Press the +/ON or –/OFF button until the desired time
is shown (2 to 60 seconds).
29
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 44 pages
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website