Scheduling
Watering Program
Planning how long to water (zone run time), when to
water (program start time) and which days to water
(watering days).
A watering program (or schedule) is the information
stored in the timer memory that determines when an
automatic watering cycle will occur and how long each
zone will water. The timer requires three basic instruc-
tions to operate automatically:
Season Adjust
Season Adjust enables the run time of all zones to be
adjusted up or down simultaneously in 10% increments
from 10% to 200%. Any increase over 100% will first
increase the time by the adjusted percentage, then split
the time in half and run the watering cycle twice.
Which days to water –called watering days.
What time to start the watering program cycle –
called program start time.
How long each zone will water during the cycle –
called zone run time
Sensor Connection Terminals
Snap-in terminals for connection of a rain sensing
device.
Watering Day
The day(s) of the week selected to water.
Watering Program Cycle
Start Time
The ECXTRA is designed to operate one sprinkler zone
at a time. When a scheduled start time occurs, the first
scheduled zone (with the lowest zone number) starts
and waters for it’s set length of run time. When the zone
has watered for its set run time, The next zone starts and
runs for its programmed run time. This is called a water-
ing cycle.
A start time is the time of day selected to begin the
watering cycle. Each program (A, B and C) can have up
to 4 separate start times.
Terminal Block
Connection point for 115 V a.c. input power in the Out-
door model timer
Time Pod
Zone
Portable electronic device used to transport ECXTRA
watering schedule information from the PC based using
CAS software to the ECXTRA timer.
Each valve controls a specific group of sprinklers called
a watering zone. The zones are generally laid out and
installed according to the type of plant material to be
watered, such as a lawn or flower bed. Each valve is
connected to a numbered terminal within the timer, iden-
tifying it as Zone 1, Zone 2, etc.
Transformer
See (Power Supply)
Valve Common Wire
One wire from each sprinkler control valve which con-
nects to the timer "COM" terminal.
Zone Run Time
The length of time a zone will operate during a watering
cycle. Run time can be set from 1 minute to 4 hours.
41
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 44 pages
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website