CONNECTING THE VALVE WIRING
1.
To provide a field common wire, attach one wire to either solenoid
lead of all sprinkler valves and master valve (optional).
2.
Attach a separate control wire to the remaining solenoid lead of
each valve. Label the control wires with the intended station
number for identification at the controller.
Caution: All wiring splices must be waterproofed to prevent
short circuits and corrosion.
A maximum load of 12 VA (0.5 amps) may be connected to
each station. A maximum load (including master valve) of
30
simultaneously. Exceeding these limits can damage the
controller.
VA (1.25 amps) may be programmed to operate
3.
Route the control and common wires into the controller cabinet
through the 2" (52mm) access opening. Remove approximately
1/2"
(13mm) insulation from the ends of each wire.
4.
5.
Attach the field common wire to one of the three valve common
terminals labeled VC/COM.
Referring to Figure 4, connect each valve control wire to the
appropriate station number terminal. If an optional master valve
is installed, connect its control wire to the terminal labeled
MV/PUMP. Tighten all terminal screws securely.
Figure 4
Pump Start
Relay
Valve Station 3
or
Master Valve
Valve Station 2
Valve Station 1
Valve Common
Installation Procedures
21
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document Type | Owner's Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)