Wall-Mount Cabinet Installation
Figure 2
1.
Position the upper support bracket on the wall
with the joggle edge up to accept the mating
upper cabinet bracket. The support bracket must
be level and at a height approximately 2" (51 mm)
above eye level to enable the Sentinel control
module display to be easily viewed.
Upper Cabinet
Bracket
2.
Mark the two mounting screw hole locations and
drill pilot holes for the screws or screw anchors.
Upper Support
Bracket
Note: Use 3/8" (10 mm) diameter fasteners to
attach the cabinet support brackets. If installing
the cabinet on dry wall or masonry, install the
appropriate size and type screw anchors.
3.
Secure the support bracket to the wall. Hang the
cabinet on the wall by engaging the upper
cabinet bracket and the support bracket.
4.
5.
6.
7.
8.
Draw a pencil line the entire length of the lower
support bracket.
Screw Anchors
Remove the cabinet from the wall and remove
the lower support bracket from the cabinet.
Place the lower support bracket on the wall
aligning it with the pencil mark.
Mark the two screw hole locations and drill pilot
holes for the mounting screws or screw anchors.
Secure the bottom support bracket to the wall.
*
Note: On early model cabinets, conduit access
holes are only provided for power and one field
wire conduit. Additional conduit access holes for
earth ground, additional field wire conduit, optional
sensor wires and optional external antenna must
be cut or punched by the installer. All conduit
access holes and knock-outs are provided on
current production cabinets.
Lower Support
Bracket
Figure 3
9.
Remove optional conduit knock-outs as required
for installation. See *Note above.
10.
Hang the cabinet on the the wall mount support
bracket. The bottom edge of the cabinet should
now rest squarely on the lower support bracket.
PROGRAMMING
INSTRUCTIONS
1
4
2
5
3
6
F1
F2
F3
F4
7
8
9
11.
12.
Secure the cabinet to the lower support bracket
using the carriage bolts and nuts removed in
Step 5 above.
O FOF N
0
O NY E S
ESC
CLUSTER / SCHEDULES
ELECT
PROGRAMS
ELECT
ENTER
Install electrical conduit for all wiring connections
per local and national code. See Figure 3.
3/4"
Flexible
Conduit From
Cabinet Base To
Junction Box
1/2"
Conduit
For Sensor
Wires (Optional)
3/4"
For Power Wires
Conduit
1/2"
Conduit For
2" Conduit For Field
Earth Ground
Wiring (25–48 Stations)
2
Wiring (12–24 Stations)
" Conduit For Field
1 1/2" Conduit For External
Antenna (Optional)
2
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)