Output Switch Operation
The 3-position switches provided on the station output
module enables local control of the station and master valve*
output.
Figure 7
*Note: The master valve terminal and switch are functional only
on station output module number 1.
The switch positions are as follows:
ON – Manually activates the terminal. The terminal will remain on
until the switch is moved to the AUTO or OFF position. An indicator
LED will illuminate when the switch is on the ON position.
OFF – Shuts off the terminal. The terminal will be inoperative
(for both automatic and manual operation) while the switch is in
the OFF position.
AUTO – Enables the terminal to be automatically controlled during
automatic or manual operation.
Caution:To prevent controller damage, do not operate
more than six stations concurrently (1.75A total load
maximum) during either manual or automatic operation.
Alarm and Sensor Connections
The Alarm Switch is designed to monitor a dry contact switch
and the alarm functionality is programmable in the system
software. The Alarm Switch input can be programmed to start or
stop programs of your choice and even follow the contact status
if desired.
Figure 8
The "Flow Signal" is designed to read "shorting pulse output"
from a Data Industrial flow meter (or equivalent). Or, if a rain
tipping bucket or evapotranspiration (ET) gauge is used, this
would to be a normally open contact type. The controller
measures the timing of the contact closures to determine if
it is a flow pulse, rain pulse or ET pulse.
1.
2.
Connect a wire pair to the alarm switch and/ or flow measuring device and route into the controller through 1/2" conduit.
Connect the wire pair to the appropriate terminals as shown in Figure 8.
Operation
The Map To Universal satellite controller does utilize a keypad or display for operation. All control functions are processed by
a designated Sentinel Satellite controller. Use the following procedure at the controlling satellite for Map to Universal set up.
The Map to Universal satellite must first have a unique 3-digit identification code or address. You may select any (unassigned)
three digit code from 000 to 999. Select the Unit Code menu option. Position the cursor using the Right and Left arrow keys
under the digit being edited. Use the number keys on the keypad to edit, them press ENTER key to save after editing.
Next, select the Map to Universal menu item which will allow you to map (or link) selected stations of a host Sentinel Satellite
to selected stations of a Map To Universal satellite. During operation, the mapped host satellite station and the corresponding
station of the Map to Universal control unit will be turned on and off by the program control of the host satellite. Use the Up
and Down arrow keys to select the host satellite station number that you want to map to. Use the Right arrow key to place the
cursor under the 3-digit field, then key in the address of the Map to Universal satellite control unit. The cursor will jump to the
2-digit
field for the station number being mapped to. Use the Up and Down arrow key to select the desired station number of
the Map to Universal control unit. Press ENTER to save the mapping information. Repeat this procedure for each satellite
station you wish to map.
5
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)