Toro Commercial Products Lubrication Oils Grease 99040SL Thistentionally Blank Lubricants

Operation
STARTING CONTROLS
See Figure 1 for the following instructions.
Electric Start
G
F
B
E
A
C
A.  Electric Start Button - The Electric Start Button
(A) activates an electric starter mounted to the
engine, eliminating the need to pull the starter han-
dle. The Electric Start Button operates on 120 Volts
AC, which is provided by connection to the extension
cord provided with units equipped with this feature.
Connect this extension cord ONLY to a properly
grounded 3 prong electrical outlet.
D
Intek
Model
Manual Start
B.  Fuel Valve - (Intek Models) The fuel valve (B) is
located under the fuel tank. It is used to turn the fuel
supply off for out-of-season storage.
B
C.  Starter Handle - The starter handle (C) connects to a
starter cord to manually start the engine. Pulling
starter handle rapidly spins the engine crankshaft,
cycles the engine, and generates the spark neces-
sary for starting the engine.
F
G
A
C
D.  Primer Button - When pressed, the primer button
(D) provides initial fuel to help start a cold engine.
Normally, pressing the primer button twice will pro-
vide enough fuel to start a cold engine.
D
Power
Built
E.  Throttle Lever - (Intek Models)The throttle lever (E)
controls the engine speed.  For best overall perfor-
mance, the throttle lever should be set to the FAST
position. Use the SLOW position only for warming the
engine, or to help prevent snow/ice freeze-up when
shutting the unit down for the day.
H
Figures 1.  Engine Controls
A.  Electric Start Button
B.  Fuel Valve (Select Models)
C.  Starter Handle
D.  Primer Button
E.  Throttle Lever (Intek Models Only)
F.  Engine Key
F.  Engine Key - The engine key (F) prevents the
engine from being started by unauthorized individu-
als. The key must be fully inserted into the key slot
for the unit to start. The key is also used to stop the
engine by pulling the key out of the key slot.
G.  Choke Knob - The choke knob (G) adjusts the
air/fuel mixture, and is used to help start a cold
engine by providing a richer mixture. Once the engine
is warm and running smoothly, the choke knob
should be set to the off position to provide a normal
air/fuel mix.
G. Choke Knob
H.  Stop Switch (Power Built Models)
H.  Stop Switch - (Power Built Models)  Switch to the
ON position to operate the engine.  Switch to the
OFF position to stop the engine.
13
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 36 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website