Electrical Systems
21
Electromagnetic Switches
Relays
Description:
Electrically operated switches that control current
flow in the circuit.
Types:
Relays
Solenoids
Testing
Relays and solenoids are tested with an Ohmmeter.
Relay test:
Terminal 85 to 86 = 76A or 86A
Terminal 30 to 87A = Normally closed
Terminal 30 to 87 = Normally open (until power is
applied to terminal 85 & 86)
Magnetic Switches (Proximity or Reed Switches)
Magnetic Switches
(Reed Switches)
Description:
Magnetically operated switches that control current
flow in the circuit.
Types:
Seat switch.
Cutting unit lift arm switch.
Testing
Magnetic reed switches are tested with an
Ohmmeter and using a magnet to close the switch.
Magnet away from switch, meter reading 0. L. (open)
Magnet close to switch, Meter reading 0.2A (closed)
Toro University Technical Training