Toro 2009 10 Intl ResCom Irrigation Catalog

EZ-Flo® Plus Jar-Top Series Plastic Residential Valves
2
5mm (1")  Electric Model
Key Features
Specifications
Options Available
Threaded jar-top bonnet system with heavy-
duty cap ring (no screws) for fast and easy
servicing without removal from the system
Flow range:
25mm (1”): 1-114 LPM (0.25-30.0 GPM)
Operating pressure:  
Reclaimed water purple solenoid assembly
and tag
DC latching solenoid* assembly
Heavy-duty PVC, glass-filled polypropylene
and stainless-steel construction (corrosion and
UV-resistant)
Slow, anti-water hammer closing
Floating bleed tube allows thermal expansion
without affecting performance
0,7-10 Bar (10-150 PSI)
Globe valve body style
*The maximum pressure for a valve  that utilizes a DC
latching solenoid is 8 bar (120  PSI).
Male and female models available
25mm (1”)
NPT/BSP
Manual On/Off
Solenoid: 60 Hz (24 VAC)
Inrush: 0.4 Amps, 11,50 VA  
Holding: 0.2 Amps, 5,75 VA
External
Additional Features
bleed screw
Tough, double-beaded Santoprene®
diaphragm for a longer life and to prevent
leaking
Jar-Top for Ease of Use
The jar-top design of the
EZ-Flo continues to make
valve installations easier.
No screws mean less time
flushing out the system
on start-up. Cleaning
for system
flushing
Solenoid: 50 Hz (24 VAC)
Inrush: 0.34 Amps, 11,50 VA
Holding: 0.2 Amps, 5,75 VA
Stainless steel
metering
system
Resilient Buna-N diaphragm seat seal
Full stainless-steel metering system
Dimensions:
Female globe:  
130 x 75 x 101mm (H x W x L)
(51⁄8” x 3” x 4”) (H x W x L)
Manual internal bleed
Manual external bleed (flush mode)
Male or
female or slip
configurations
the diaphragm area is
uncomplicated as it requires
no tools. And putting the
diaphragm back in the valve
is even easier since it only fits
in one way.
Encapsulated solenoid with captured hex
plunger and spring
Optional flow control (FC)
Extended 3 year warranty
Male globe:
130 x 75 x 140mm (H x W x L)
(51⁄8” x 3” x 51⁄2”) (H x W x L)
DCLS-P latching
solenoid assembly
EZ-Flo Plus Series Friction Loss
Data (Metric)
LPM Flow
1
19
38
57
76
114
Friction
Loss (Bar)
EZ-Flo Plus Valves – Specifying Information
,14
,24
,28
,21
,23
,43
EZX  - XX -   X4
EZ-Flo Plus Series Friction Loss
Data (English)
Threads
Flow Control
Body Threads
3–Female, BSP
Solenoid
Size
F–NPT
P–BSP
0–w/o F.C.
2–with F.C.
0–Slip
0–60Hz
5–50Hz
6–None
4–25mm (1")
GPM Flow
.25
5
10
15
20
30
1–M x M, NPT
x M, BSP
5–Male x Barb
6–Female, NPT
2–M
Friction
Loss (PSI)
9–DC
Latching
2.0
3.5
4.0
3.0
3.3
4.3
Solenoid
Note: For optimum sprinkler performance when  design-
ing a system, calculate total friction  loss to ensure suffi-
cient downstream pressure. Flow rates are  recommended
not to exceed 0,35 Bar (5  PSI) loss.
For Example: When ordering a Male  x Male, BSP thread, 25mm (1") EZ-Flo Plus Valve with  flow control and a
50Hz
solenoid, you would order:
EZP-22-54
Note: Some model combinations are not  available. Consult your local Toro distributor for availability in select  markets.
57
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 92 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website