EZ-Flo® Plus Jar-Top Series Plastic Residential Valves
2
5mm (1") Electric Model
Key Features
Specifications
Options Available
•
Threaded jar-top bonnet system with heavy-
duty cap ring (no screws) for fast and easy
servicing without removal from the system
• Flow range:
25mm (1”): 1-114 LPM (0.25-30.0 GPM)
• Operating pressure:
• Reclaimed water purple solenoid assembly
and tag
• DC latching solenoid* assembly
•
Heavy-duty PVC, glass-filled polypropylene
and stainless-steel construction (corrosion and
UV-resistant)
Slow, anti-water hammer closing
Floating bleed tube allows thermal expansion
without affecting performance
0,7-10 Bar (10-150 PSI)
• Globe valve body style
*The maximum pressure for a valve that utilizes a DC
latching solenoid is 8 bar (120 PSI).
•
Male and female models available
•
•
•
•
25mm (1”)
NPT/BSP
➊
Manual On/Off
• Solenoid: 60 Hz (24 VAC)
Inrush: 0.4 Amps, 11,50 VA
Holding: 0.2 Amps, 5,75 VA
➋ External
Additional Features
•
bleed screw
Tough, double-beaded Santoprene®
diaphragm for a longer life and to prevent
leaking
Jar-Top for Ease of Use
The jar-top design of the
EZ-Flo continues to make
valve installations easier.
No screws mean less time
flushing out the system
on start-up. Cleaning
for system
flushing
•
Solenoid: 50 Hz (24 VAC)
Inrush: 0.34 Amps, 11,50 VA
Holding: 0.2 Amps, 5,75 VA
➌
➍
Stainless steel
metering
system
• Resilient Buna-N diaphragm seat seal
•
•
• Full stainless-steel metering system
•
• Dimensions:
• Female globe:
130 x 75 x 101mm (H x W x L)
(51⁄8” x 3” x 4”) (H x W x L)
Manual internal bleed
Manual external bleed (flush mode)
Male or
female or slip
configurations
the diaphragm area is
uncomplicated as it requires
no tools. And putting the
diaphragm back in the valve
is even easier since it only fits
in one way.
Encapsulated solenoid with captured hex
plunger and spring
Optional flow control (FC)
Extended 3 year warranty
•
Male globe:
130 x 75 x 140mm (H x W x L)
(51⁄8” x 3” x 51⁄2”) (H x W x L)
•
•
DCLS-P latching
solenoid assembly
EZ-Flo Plus Series Friction Loss
Data (Metric)
LPM Flow
1
19
38
57
76
114
Friction
Loss (Bar)
EZ-Flo Plus Valves – Specifying Information
,14
,24
,28
,21
,23
,43
EZX - XX - X4
EZ-Flo Plus Series Friction Loss
Data (English)
Threads
Flow Control
Body Threads
3–Female, BSP
Solenoid
Size
F–NPT
P–BSP
0–w/o F.C.
2–with F.C.
0–Slip
0–60Hz
5–50Hz
6–None
4–25mm (1")
GPM Flow
.25
5
10
15
20
30
1–M x M, NPT
x M, BSP
5–Male x Barb
6–Female, NPT
2–M
Friction
Loss (PSI)
9–DC
Latching
2.0
3.5
4.0
3.0
3.3
4.3
Solenoid
Note: For optimum sprinkler performance when design-
ing a system, calculate total friction loss to ensure suffi-
cient downstream pressure. Flow rates are recommended
not to exceed 0,35 Bar (5 PSI) loss.
For Example: When ordering a Male x Male, BSP thread, 25mm (1") EZ-Flo Plus Valve with flow control and a
50Hz
solenoid, you would order:
EZP-22-54
Note: Some model combinations are not available. Consult your local Toro distributor for availability in select markets.