TDC Series Controller
The TDC (Turf Decoder Controller)
system provides a durable, cost-
effective alternative to traditionally
wired irrigation control systems. Using
a 2-wire path to communicate to
buried decoders, the TDC is vandal-
resistant, easy-to-install and easy to
expand.
Key Features
Additional Features
Specifications
• Operating temperature: 0-60° Celsius
(0° to 140° F)
• Input power: 120 or 220/240 V.a.c.,
50/60 Hz. Transformer
• Station output power: Up to 38 V.a.c. max;
3 amps max output
• UL/cUL, TUV, CE, C-Tick, and SAA
approved
• Wiring-two wire path: Jacketed, twisted pair
14 AWG to 15,000 ft.
• Wiring-decoder to solenoid: Standard pair 14
AWG to 400 ft.
• Cabinet Dimensions:
•
Modular Design with a base of 100 stations
and can be upgraded to 200 stations
• 20 KV surge protection with proper
grounding of 10 Ohms or less at the
controller
• 10 independent irrigation programs
• Six start times per program
• Day of the week programming, odd/even,
interval (1-31 days)
• Advanced Diagnostics provides true two-way
communication with each decoder in the
field, providing communication verification
to decoders in the field
•
Detects shorted or open solenoid conditions,
making troubleshooting easier
•
Day Exclusion (remove a day from standard
program)
• Operates DC Latching Solenoids, which use
significantly less power than AC solenoids
•
Programmable master valve and pump start,
by program and by station
•
•
•
Water budget by controller, by program and
by station (Season Adjust) 0 to 250% in 1%
increments
Installing and servicing are quick and simple
thanks to the large LCD display and the
industry’s most intuitive interface
•
•
•
Manual start of each station or entire program
Non-volatile memory retains programming
Self-diagnostics circuit breaker skips shorted/
open stations and continues watering
33.5 x 35.5 x 15cm
13” x 14” x 6” (H x W x D)
•
Available as a stainless steel pedestal
CDEC-PED-XXX
•
•
•
•
InterStation Delay
1 minute to 5 hour cycle and soak
Two-way confirmation of decoder activation
Activate up to 20 solenoids at up to
4.5 kilometers (2.8 miles) away
Decoders able to operate 1 or 2 solenoids per
station
TDC Series Controller
Specifying Information
•
•
•
•
•
Programmable rain delay up to 31 days
Water window calculator
10-digit alpha-numeric zone identification
Remote-Ready and RainSensor-compatible
®
Upgradeable to Toro Sentinel Central
Control
CDEC - XXX - XXX
Model
Cabinet
Description
CDEC−2-wire
Controller
SA−Wall
Mount
Metal
Cabinet
100−100
Stations
200−200
Stations
PED−Stainless
Steel
Pedistal
For Example: A TDC controller with 200 stations, you
would specify: CDEC-SA-200
1-, 2-, and 4-station Decoders
Specifying Information
CDEC - ISP - X
Model
Type
Desription
Two Wire Path
CDEC—2-wire
ISP—Integrated Surge
Protection
1—Single Station Decoder
2—Two Station Decoder
Surge Protection.
Decoder
1
per 300m (1000 ft)
4—Four
Station Decoder**
DEC-SG-LINE
For Example: A TDC decoder with 2 stations, you would specify:
TMR-1
TriComm
RainSensor
Compatible
CDEC-ISP-2
Compatible Compatible*
*Future Enhancement
**Future Option
77
Categories | Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)