220
Series Brass Valves (continued)
Specifications
Inrush: 60 Hz, 12 amps
Holding: 60 Hz, 0.1 amps
Solenoid: 50 Hz 24 VAC
Inrush: 0,30 amps, 7,2 VA
Holding: 0,20 amps, 4,8 VA
Options Available
Pressure regulating models:
Outlet: EZR–30
0,3–2,0 Bar, ±  0,2 Bar (5–30 PSI, ±   3
PSI)
Outlet: EZR-100
0,3–7,0 Bar, ±  0,2 Bar (5–100 PSI, ±   3
PSI)
Inlet: 1,0–15 Bar (15-220 PSI)
Minimum pressure differential (between inlet
and outlet): 0,7 Bar (10 PSI)
Burst pressure safety rating: 52 Bar (750 PSI)
Recommended flow range:
DC Latching solenoid assembly
24 V DC solenoid assembly
Reclaimed water purple solenoid assembly
and tag (RW60–Kit)
24 VAC potted solenoid assembly
50–60 Hz, 60cm (24”) leads
Inrush: 0,37 amps, 8,80 VA
Holding: 0,30 amps, 7,20 VA
EZR–30 — 0,3–2,0 Bar  
(5–30 PSI) pressure-regulation module
EZR–100 — 0,3–7,0 Bar  
(5–100 PSI) pressure-regulation module
NPT/BSP threads
25mm — 19–95 LPM
1” — 5–25 GPM)
40mm — 75–227 LPM
11⁄2” — 20–60 GPM)
50mm — 150–303 LPM  
(2” — 40–80 GPM)
(
(
Dimensions:
25mm — 146 x 127mm  
(1” — 53⁄4” H x 5” W)
40mm — 165 x 152mm  
(11⁄2” — 61⁄2” H x 6” W)
50mm — 191 x 178mm  
(2” — 71⁄2” H x 7” W)
75mm — 223 x 216mm  
(3” — 83⁄4” H x 81⁄2” W)
Body styles: Globe valve, female threads
(except 75mm (3”) model–angle)
75mm — 303–681 LPM
(3” — 80–180 GPM)
Operating pressure:
Electric — 0,7–15 Bar (10–220 PSI)
SpikeGuard   Solenoid: 24 VAC (50/60 Hz)
220
114
Series Friction Loss Data (Metric – LPM)
Model - Electric
19
38
57
76
151
189
227
265
303
378
454
568
644
681
757
946
1136
1325
25mm (1")
0,14
0,17
0,10
0,17
0,27
0,38
0,29
0,07
0,61
0,32
0,14
40mm (11
⁄2")
0,34
0,14
0,36
0,17
0,38
0,21
0,50
0,24
0,15
50mm (2")
0,41
0,17
0,52
0,17
0,69
0,21
0,83
0,22
0,97
0,24
75mm (3")
0,26
0,28
0,31
0,34
Model - Hydraulic
25mm (1")
0,01
0,07
0,10
0,17
0,07
0,38
0,10
0,03
0,48
0,17
0,07
40mm (11
⁄2")
0,21
0,08
0,31
0,10
0,41
0,17
0,55
0,21
50mm (2")  
0,38
0,48
0,69
0,79
1,00
Flow rates are recommended not to  exceed 0,3 bar loss. Values shown in Bar.
Notes: For optimum performance when designing  a system, calculate total friction loss to ensure sufficient downstream  pressure. For optimum regulation performance, size
regulating valves toward the higher flow  ranges.
220
30
Series Friction Loss Data (English – GPM)
Model - Electric
5
10
15
20
40
50
60
70
80
100
120
150
170
180
200
250
300
350
Effluent Labels Included
New in 2008, all 220 Brass  valves include
reclaimed label and warning tag.
1" (25mm)
2.0
2.5
1.5
2.5
3.9
5.5
8.9
4.6
2.0
11
⁄2" (40mm)
4.2
4.9
2.0
5.2
2.5
5.5
3.0
7.2
3.5
2.2
2" (50mm)
1.0
6.0
2.4
7.5
2.5
10.0
3.0
12.0
3.2
14.0
3.5
3" (75mm)
3.7
4.0
4.5
5.0
Model - Hydraulic
1" (25mm)
<1.0
<1.0
1.5
2.5
5.5
1.5
7
11
⁄2" (40mm)
<1.0
2.5
1.0
3
4.5
1.5
6.0
2.5
8.0
3.0
2" (50mm)
<1.0
1.1
5.5
7.0
10.0
11.5
14.5
Flow rates are recommended not to  exceed 5 PSI loss. Values shown in PSI.
Notes: For optimum performance when designing  a system, calculate total friction loss to ensure sufficient downstream  pressure. For optimum regulation performance, size regulating valves toward  the higher
flow ranges.
64
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 92 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website