Toro 2009 10 Intl ResCom Irrigation Catalog

P-220 Series Plastic Valves (continued)
Specifications
Solenoid: 24 VAC (50 Hz)
Inrush: 0,30 amps, 7,2 VA
Holding: 0,20 amps, 4,8 VA
Dimensions:
25mm—171mm x-92mm  
(1” — 63⁄4” H x 35⁄8” W)
40mm—184mm x-92mm  
(11⁄2” — 71⁄4” H x 35⁄8” W)
50mm—241mm x-156mm  
(2” — 91⁄2” H x 61⁄8” W)
75mm—273mm x-156mm  
(3” — 103⁄4” H x 61⁄8” W)
Options Available
Outlet: EZR-100
0,3–7,0 Bar, ±  0,2 Bar (5–100 PSI, ±   3 PSI)
Inlet: 1,0–15 Bar (15-220 PSI)
Minimum pressure differential
(between inlet and outlet): 0,7 Bar (10
PSI)
Recommended flow range:
DC Latching solenoid assemblies
24 V DC solenoid assembly
Reclaimed water purple solenoid assembly
and tag
24 VAC potted solenoid assembly
50–60 Hz, 60cm (24”) leads
25mm—19–114 LPM
1” — 5–30 GPM)
40mm—114–265 LPM
11⁄2” — 30–70 GPM)
50mm—300–530 LPM
2” — 80–140 GPM)
75mm—568–852 LPM
3” — 150–225 GPM)
Operating pressure:
Electric — 0,7–15 Bar (10–220 PSI)
(
(
Burst pressure safety rating: 52 Bar (750 PSI)
Body styles: Globe/angle valve,
female-threads
(
Inrush: 0,37 amps, 8,80 VA
Holding: 0,30 amps, 7,20 VA
(
SpikeGuard   Solenoid: 24 VAC (50/60 Hz)
EZR–30 — 0,3–2,0 Bar  
(5–30 PSI) pressure-regulation module
EZR–100 — 0,3–7,0 Bar  
(5–100 PSI) pressure-regulation module
Inrush: 60 Hz, 12 amps
Holding: 60 Hz, 0.1 amps
Outlet: EZR–30
0,3–2,0 Bar, ±
0,2 Bar (5–30 PSI, ±  3 PSI)
NPT/BSP threads
P-220 Series Friction Loss Data (Metric – LPM Flow)
Valve Wire Sizing (Metric)
Config-
Size
Maximum One-way Distance (in meters) Between Controller and Valve
Using Spike-Guard   Solenoid*
40
60
80
100
120
140
160
180
200
250
300
350
400
450
500
550
600
700
800
900
1000
1100
uration
Ground
Wire
(mm)
Control Wire (mm)
25mm
(1")
Globe
Angle
0,29
0,29
0,25
0,25
0,25
0,21
0,26
0,20
0,32
0,21
0,43
0,29
0,55
0,38
0,69
0,49
0,82
0,61
1.02
621.79
1.29
1.63
2.05
2.59
3.26
4.11
40mm
Globe
Angle
0,12    0,14   0,18    0,23    0,28   0,43    0,62    0,85   1,11
0,09                                                                          0,85
1.02
1.29
1.63
2.05
2.59
3.26
4.11
768.10
896.11
999.74
1,078.99
777.24
1,133.86
1,712.98
2,529.84
3,596.64
4,895.09
6,339.84
7,784.59
1,176.53
1,804.42
2,731.01
4,017.26
5,721.10
7,784.59
10,082.78
(1½")
0,10
0,13
0,17
0,22
0,34
0,48
0,65
768.10
993.65
1,219.20
1,578.86
1,938.53
2,261.62
2,529.84
2,731.01
1,420.37
1,938.53
2,511.55
3,078.48
3,596.64
4,017.26
50mm
Globe
Angle
0,14    0,20   0,25    0,32    0,40   0,48    0,54
0,08    0,12   0,15    0,19    0,24   0,29    0,32
896.11
1,219.20
1,420.37
1,591.06
1,603.25
1,816.61
2,261.62
3,078.48
4,017.26
4,895.09
5,699.76
(2")
999.74
75mm
(3")
Globe
Angle
0,18
0,14
0,24
0,19
0,32
0,26
0,41
0,34
0,52
0,43
0,65
0,54
1,078.99
1,133.86
1,176.53
Flow rates are recommended not to  exceed 0,35 Bar loss.
Values shown in Bar. For kPa  values, multiply tabular values by 100.  For Kg/cm2 values,  multiply tabular values by 1,02.
Note: For optimum performance when designing  a system, be sure to calculate total friction loss to  ensure sufficient downstream pressure. For optimum
regulation performance, size regulating valves toward  the higher flow ranges.
Valve Wire Sizing (English)
P-220 Series Friction Loss Data (English – GPM Flow)
Maximum One-way Distance (in ft.) Between Controller and Valve Using
Config-
uration
Spike-Guard   Solenoid*
Size
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
180
200
225
250
275
300
Ground
Wire
(AWG)
Control Wire (AWG)
Globe
Angle
4.00
4.00    4.20   3.10    2.70    4.80    7.90
4.20
3.20
4.10
7.20
10.90
1
"
18
16
14
12
10
8
6
(25mm)
18
16
14
12
10
8
2040
2520
2940
3280
3540
3720
3860
2520
3260
4000
4660
5220
5260
5960
2940
4000
5180
6360
7420
8300
8960
3280
4660
3540
5220
3720
5620
3860
5920
Globe
Angle
1.60
1.30
2.30
1.60
3.60
2.80
5.20
4.00
7.00
5.50
9.20
7.10
11.70
9.00
14.40
11.00
17.50
13.30
1½"
(40mm)
6360
7420
8300
8960
Globe
Angle
2.10
1.20
2.70
1.60
3.30
2.00
4.00
2.40
4.80
2.80
5.60
3.30
6.50
3.90
7.50
4.40
8.05
5.10
2"
8240
10100
13180
16060
18700
11800
16060
20800
25540
13180
18770
25540
33080
(50mm)
10100
11800
13180
Globe
Angle
2.50
1.90
3.00
2.40
4.10
3.30
5.30
4.30
6.70
5.50
8.30
6.90
10.10
8.50
3"
(75mm)
6
Flow rates are recommended not to  exceed 5 PSI loss. Values shown in PSI.
62
Product Specification
CategoriesSprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 92 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website