Series connection for voltage readings
Series connection for voltage readings
Connecting a voltmeter in series checks the com-
plete circuit for continuity. A meter reading of bat-
tery voltage, indicates that there is continuity from
the battery, to the load and back to the battery. A
meter reading of 0.0 volts indicates an open circuit.
Figure 16
Measuring Resistance With an Ohmmeter
Measuring Resistance With an Ohmmeter
1.
2.
4.
Isolate the load from the circuit
Connect meter across load
Read resistance on meter.
High Amperage Circuit Testing
Generally, testing electric circuits over 10 amps will
exceed most DVOM’s capacity.
Figure 17
AC/DC Current Transducer (Inductive)
Measuring current with AC/DC Current Trans-
ducer (Inductive)
1.
2.
3.
Clamp meter around wire
Activate system
Read amperage on meter