Common switches
Common switches
Description:
Manually operated switches that control current
flow in the circuit.
Toggle switches
Push button
Commonly used for Neutral, light, horn and seat
switches.
Figure 26
Key switch
Key switch
Used to control unit starting, running,
accessories
and
Testing
Test Switches with an Ohmmeter. Look for
continuity when closed, infinity when open.
When the switch is in the circuit, the switch is
tested with a voltmeter.
Figure 27
Relays
Electromagnetic switches
Description:
Electrically operated switches that control current
flow in the circuit.
Types:
1.
2.
Relays
Solenoids
Figure 28
Testing
Relays and solenoids are tested with an Ohmmeter.
Relay test
Terminal 85 to 86 = 76 A or 86 A.
Terminal 30 to 87A = Normally closed
Terminal 30 to 87 = Normally open (until power is
applied to terminal 85 & 86).
Figure 29