Toro Commercial Products Hydraulics Hydrostatics Schematics Test Equipment 82356SL Rev B

Introduction To Hydraulic Schematics
Accurate diagrams  of  hydraulic circuits  are essen-
tial  to the  technician  who  must repair  it.  The dia-
gram  shows  how  the  components  will  interact. It
shows the technician how  it works, what each com-
ponent should be doing and where the oil should be
going, so  that he can  diagnose and repair  the sys-
tem.
CIRCUIT DIAGRAMS
There are two types of circuit diagrams.
A:   Cutaway  Circuit  Diagrams show  the  internal
construction  of the  components  as well  as  the oil
Figure 2
flow paths.  By using colors,  shades or various  pat-
terns  in the  lines  and  passages, they  are  able to
show many different conditions of pressure and
flow (Fig 1).
1
. Schematic symbol systems
A:  I.S.O  = International Standards  Organization.
B: A.N.S.I. = American National Standards  Institute
C:  A.S.A  = American  Standards  Association
D:  J.I.C.  = Joint Industry Conference
A combination  of these  symbols are  shown  in this
manual. There  are difference between the  systems
but there  is enough  similarity so  that if  you under-
stand the symbols in this manual  you will be able to
interpret other symbols as well.
2.
Hydraulic reservoirs
A
B
C
Figure 1
Figure 3
B:
Schematic   Circuit   Diagrams   are  usually
Reservoirs  (Fig 3)  are  pictured as  either  an open
square meaning it is a  vented reservoir, or a closed
reservoir meaning  that it is a  pressurized reservoir.
Every system  reservoir has  at least  two lines  con-
nected to  it, and some have  many more. Often  the
components that  are connected to  it are spread  all
over  the  schematic.  Rather  than  having  a  lot  of
confusing lines all  over the schematic, it  is custom-
ary  to  draw  individual  reservoir  symbols close  to
the  component.  Similar  to  the  ground  symbol   in
some  wiring  schematics.  The  reservoir  is  usually
the only component to be pictured more than once.
preferred for troubleshooting because of their  ability
to  show current  and potential  system  functions. A
schematic   diagram   is   made    up   of   consistent
geometric  symbols  for  the  components  and  their
controls and connections (Fig 2).
7
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 32 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website