Ariens Sno Thro 921001 2 3 4 ST824E ST1027LE ST1130DLE ST924DLE Snow Blower Owners Manual

NOTE: After the chute rod has been inserted through
the hex hole in the control assembly, placing the unit in
the service position (see Service Position on page 18)
will ease alignment and installation of the hair pin.
11. Tighten pedestal hardware to 15 – 31 lbf-ft (20 –
42 N•m).
12.
Make sure the discharge chute rotates left and
right when you push the discharge chute control
lever left and right.
8.
Secure the chute rod to the control assembly with
the hair pin removed in step 6. Insert the hair pin
with the loop end to the left of the chute rod so the
control assembly follows a full range of travel.
Install Discharge Chute and Discharge Chute
Crank (921001)
(Figure 11)
921002, 003, 004
1.
Grease underside of discharge chute ring (if not
already greased).
3
2
2.
3.
Remove mounting hardware from auger housing.
4
Install discharge chute over opening in the auger
housing. Finger tighten the mounting hardware
removed in step 2.
NOTE: Leave discharge chute pedestal loose to help
install the chute rod and connect it to the control
assembly.
1
921001
1.
2.
3.
4.
Chute Rod
4
Gear Cover
Control Assembly
Hair Pin
1
Figure 9
OS7432
3
9.
Insert the chute lock cable fitting into the bracket
on the chute pedestal, and then connect the
chute lock cable to the lock teeth by fitting the
cable ball end into the slot on the lock teeth. See
Figure 10.
2
NOTE: Press down on lock teeth with your finger to
align the cable ball end with the slot (Figure 10).
1.
2.
3.
4.
Chute Rod
Gear Cover
Control Panel
Hair Pin
Figure 11
OS7061
4.
5.
Insert the short end of the chute rod into the hole
in the front of the control panel.
Connect the chute crank to the pinion gear on
chute with spring clip.
IMPORTANT: Rotate the discharge chute to the left
when tightening the pedestal hardware to ensure
clearance between the discharge chute and the belt
cover.
6.
Tighten pedestal hardware to 15 – 31 lbf-ft (20 –
42
N•m).
Deflector Remote (921002, 003, 004)
Figure 10
OS7271
Connect the cable end to the cable anchor on the
discharge deflector before clipping the cable to the
cable bracket on the discharge chute.
10.
Replace the gear cover removed in step 4.
IMPORTANT: Rotate the discharge chute to the left
when tightening the pedestal hardware to ensure
clearance between the discharge chute and the belt
cover.
1.
Route deflector remote cable along the left side of
the chute pedestal.
GB - 9
Product Specification
CategoriesAriens Snow Blower Manuals, Snow Blower Manuals
Tags, , , , , , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 34 pages
Document TypeOwner's Manual
LanguageEnglish
Product BrandAriens, Snow Blower
Document File TypePDF
Publisherariens.com
Wikipedia's PageAriens
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website