English / USA
Releasing a Trapped Auger
Cleaning the Air Filter
Working with Shaft Extension
(special accessory)
Do not fit the shaft extension until the full
length of the auger is in the hole.
1
Starting a hole with the shaft
extension fitted increases the risk of
personal injury because the unit is
then at chest height and cannot be
kept properly under control.
A
For the same reason the shaft
extension must be removed before
the auger is pulled out of the hole.
3
2
If the auger jams in the drill hole - shut off
the engine immediately.
If there is a noticeable loss of
engine power
:
:
:
Move the slide control in direction of
:
:
:
:
Turn choke knob to g
Press in the tab (1).
Remove the filter cover (2).
c to $
Engage the auger brake by moving
the activating lever to position A.
Clean away loose dirt from inside of
Now rotate the whole machine to
the left – counterclockwise – to
unwind the auger from the ground.
filter cover and around the filter.
:
Remove the filter element (3) and
check it – if it is dirty or damaged, fit
a new element.
:
:
Fit the flter element in the filter
cover.
Push the filter cover into position.
18
BT 120 C
Categories | Auger Drill Manuals, Stihl Auger Drill Manuals |
---|---|
Tags | STIHL BT 120 C |
Download File |
|
Document Type | Operator's Manual |
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Auger |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)