Let go of rope slowly so that it winds
onto the rotor.
The starter grip must locate firmly in
the rope guide bush. If the grip
droops to one side: Add one more
turn on rope rotor to increase spring
tension.
Replacing the rewind spring
:
Remove the rope rotor as described
under "Replacing the starter rope”.
The bits of spring in the fan housing
might still be under tension and
could fly apart when you take them
out of the housing. To reduce risk of
injury, wear eye and face protection
and work gloves.
2 3
4
:
Thread the rope through the rotor
and secure it with a simple
overhand knot.
Tensioning rewind spring
:
Make a loop in the unwound
starter rope and use it to turn
the rope rotor six full revolutions
clockwise.
:
:
Coat rope rotor bearing bore with
non-resinous oil**.
Slip rotor over starter post – turn it
back and forth to engage anchor
loop of rewind spring.
Refit the pawl (4).
Fit the washer (3).
Install spring clip (2) on starter post
and engage it on the pawl's peg –
the spring clip must point clockwise.
:
:
Hold the rotor steady – pull out and
straighten the twisted rope.
Release the rope rotor.
:
:
:
**
see “Special Accessories”
BT 45
25
Categories | Auger Drill Manuals, Stihl Auger Drill Manuals |
---|---|
Tags | STIHL BT 45 |
Download File |
|
Document Type | Operator's Manual |
Language | English, Español |
Product Brand | STIHL. Stihl Inc, USA - Corporate phone: (757) 486-9100. International Support Information: http://stihl.com Email: info@stihl.com, Auger |
Document File Type | |
Publisher | stihl.com |
Wikipedia's Page | Stihl |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)