Repair instructions
Air intake system – refitting
4
1
Fit the inlet manifold (A) through the insulating
plate in the carburettor flange cut-out (B), and
check that the insulating plate’s impulse tube sits
correctly in the inlet manifold. Fit the perforated
brass support ring in the inlet manifold.
Refit the carburettor. Screw in the carburettor bolts
directly from behind without lifting the carburettor
assembly, tightening to a torque of 1–1.5 Nm. It is
important to hold the carburettor flange securely
when tightening the bolts to prevent the inlet mani-
fold from moving.
2
4
Fit the air intake system on the cylinder and snap
the insulating plate into position. Check carefully
that the impulse tube is correctly seated against
the cylinder’s impulse channel.
Push down the rear carburettor mounting into the
rubber bushings using a small screwdriver. Re-
move tool 502 54 17-01.
3
5
Refit:
•
•
cylinder, see special instructions
silencer support (does not apply to 340, 345,
350)
•
•
•
•
air filter
HT lead
cylinder cover
after the test run retighten the silencer bolts to a
torque of 8–10 Nm
Position tool 502 54 17-01 between the carburettor
flange and the insulating plate.
English – 37
Categories | Chainsaw Manuals, Husqvarna Chainsaw Manuals |
---|---|
Tags | Husqvarna 340, Husqvarna 345, Husqvarna 346XP, Husqvarna 350, Husqvarna 351, Husqvarna 353 |
Model Year | 2003, 2004, 2005, 2006 |
Download File |
|
Document Type | Operator's Manual |
Language | English |
Product Brand | Husqvarna, Chainsaw |
Document File Type | |
Publisher | husqvarna.com |
Wikipedia's Page | Husqvarna |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)