Toro 08156SL Service Manual ProCore Processor Preface Publication

2.
Conduct a hydrometer test of the battery electrolyte.
A.  Check the voltage across  the battery terminals
prior to testing the battery. If the voltage is less than
IMPORTANT: Make sure the area around the cells is
clean before opening the battery caps.
12.4
VDC, recharge the battery.
B.  If the battery has recently been charged, remove
the battery  surface  charge before  performing the
loadtest.Disconnect  theengine fuelstopsolenoidto
prevent the engine from starting. Engage the starter
motor  for 10  seconds  to remove  battery  surface
charge. Reconnect the fuel stop solenoid.
A.  Measure the specific gravity of each  cell with a
hydrometer.  Draw  electrolyte  in  and  out   of  the
hydrometer barrel prior to taking a reading to warm--
up the hydrometer. At the same time take the tem-
perature of the cell.
B.  Temperature correct each cell reading. For each
C. Make surebattery terminals arefreeofcorrosion.
10
specific gravity reading. For each 10oF (5.5oC) be-
oF (5.5oC) above 80oF (26.7oC) add 0.004 to the
D. Measure  the temperature of  the center  battery
cell.
low 80oF (26.7oC) subtract 0.004  from the specific
gravity reading.
E.  Connect a battery load tester to the battery termi-
nals following the load tester manufacturer’s in-
structions.  Connect  a  digital  multimeter  to  the
battery terminals.
Example: Cell Temperature
Cell Gravity
100oF
1.245
100
(37.7
20
(11
oF minus 80oF equals 20oF
oC minus 26.7oC equals 11.0oC)
oF multiply by 0.004/10oF equals 0.008
oC multiply by 0.004/5.5oC equals 0.008)
F.  Applyatestloadof270amps(onehalftheCrank-
ing Performance  rating  of the  battery) for  15  se-
conds.
ADD (conversion above)
Correction to 80oF (26.7oC)
0.008
1.253
G. Take a voltage reading after 15 seconds, then re-
move the load.
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cellspecificgravityislessthan1.225,chargethebat-
tery. Charge at the recommended rate and time giv-
en in Charging or until specific gravity of all cells is
H. Using  the table below,  determine the minimum
voltage for the cell temperature reading:
1.225
orgreater withthedifferenceinspecificgravity
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
Minimum
Voltage
Battery Electrolyte
Temperature
9.6
9.5
9.4
9.3
9.1
8.9
8.7
8.5
70oF (and up)
60oF
21.1oC (and up)
15.6oC
3.
Perform a  high--discharge test  with an  adjustable
load tester.
50oF
40oF
10.0oC
4.4oC
Thisisoneofthemostreliablemeansoftestingabattery
asitsimulatesthecold--crankingtest.Acommercialbat-
tery load tester is required to perform this test.
30oF
20oF
10oF
0oF
--1.1oC
--6.7oC
--12.2oC
--17.8oC
CAUTION
I.   If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
Follow  the battery  load  tester  manufacturer’s
instructions when using a battery load tester.
Electrical System
Page 5 -- 14
ProCore Processor
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 122 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website