Toro 02104SL Rev D Groundsmaster 4500 D 4700 D Service Manual

Start, Neutral, Seat, Cutting Deck, Parking Brake, and High Temperature Relays
The relays  are located under the  console cover (Fig.
23).
The wiring harness is tagged to identify each relay.
1
NOTE:  Machines
with
serial
numbers
above
230000000
use a standard  control module to monitor
3
several switches. These machines  do not use a start,
neutral, seat, parking brake or high temperature relay.
4
2
5
6
NOTE:  The relays may be manufactured by one of two
different manufacturers. Verify manufacturer name and
part number before performing the resistance check on
the relay coil.
NOTE:  Prior to taking small resistance readings with a
digital multi meter, short the meter test leads together.
The meter will display a small resistance value (usually
7
8
9
0.5
ohms or less). This resistance is due to the internal
Figure 23
resistance of the meter and test leads. Subtract this val-
ue from from the measured value of the component you
are testing.
1.
2.
3.
4.
5.
Control panel
K8 relay: seat
K9 relay: neutral (behind)
K7 relay: parking brake
K3 relay: GM4700 deck 7
6.
7.
8.
9.
K2 relay: decks 1 -- 5
K6 relay: high temp
K5 relay: start
K1 relay: GM4700 deck 6
1.
Verify coil resistance between terminals 85  and 86
with a multimeter (ohms setting):
86
85
87A
87
A.  For the Tyco Electronics relay (#VF4--65F11), re-
sistance should be from 71 to 88 ohms.
87
87A
86
85
B.  For the Hella Electronics relay (#66211), resist-
ance should be from 70 to 80 ohms.
30
2.
Connectmultimeter (ohmssetting) leadstorelayter-
30
minals 30 and  87. Ground terminal 86 and  apply +12
VDC to terminal 85. The relay should make and break
continuity between terminals 30 and 87 as +12 VDC is
applied and removed from terminal 85.
3.
Disconnect voltage from terminal 85 and multimeter
lead from terminal 87.
4.
Connectmultimeter (ohmssetting) leadstorelayter-
minals 30 and 87A. Apply +12 VDC to terminal 85. The
relay should make and break continuity between termi-
nals 30 and 87A as +12  VDC is applied and removed
from terminal 85.
Figure 24
5.
Disconnect voltage  and multimeter leads from  the
relay terminals.
Electrical System (Rev. A)
Page 5 -- 16
Groundsmaster 4500--D/4700--D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 274 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website