Toro 02104SL Rev D Groundsmaster 4500 D 4700 D Service Manual

Mow Circuit
Hydraulic flow for themow circuit is supplied by twosec-
tions of the gear pump (P1 and P2). Gear pump section
(P1) supplies hydraulic flow to decks 2, 3, and 5 (also 7
on  the GM  4700--D),  while gear  pump  section (P2)
supplies decks 1 and 4 (also 6 on the GM 4700--D).
stopping rate of the blade when the solenoid valves are
de--energized as the PTO switch is turned OFF. Decks
#6 and #7 are controlled by solenoid valve (SV2), logic
cartridge (LC2), and brake relief cartridge (RV9).
Returnoilfromthedeckmotorsisdirectedtotheoilcool-
er and oil filter. Deck motor case drain leakage returns
to the hydraulic reservoir.
On the Groundsmaster 4500--D, hydraulic flow from the
two  pump  sections   is  controlled  by  two   hydraulic
manifolds each  equipped  with a  solenoid controlled,
proportional relief valve  (PRV1/PRV2), logic cartridge
(LC1), and brake relief cartridge (RV8). When the PTO
switch is OFF (or if the decks are raised), the deck sole-
noid valves (PRV1/PRV2) are not  energized, allowing
hydraulic flow to by--pass the deck motors through the
manifold. When the PTO switch is  turned ON with the
decks lowered, the solenoid valves (PRV1 and PRV2)
energize, causing a  shift of the logic cartridges  (LC1)
andallowinghydraulicflowtothedeckmotors.Brakere-
lief cartridges  (RV8)  control the  stopping rate  of the
bladewhenthesolenoidvalvesarede--energizedasthe
PTO switch is turned OFF.
Maximum mow circuit pressure is limited at each deck
manifold  by the  proportional  relief valve  (PRV1 and
PRV2).The deck relief valve pressure is3500 PSI.Mow
circuit pressure  can be measured  at port (G1)  of the
deck control manifold.
#4
Deck
#1 Deck
#5 Deck
On the Groundsmaster 4700--D, hydraulic flow from the
two pump sections is controlled by two hydraulic man-
ifolds each equipped with a solenoid controlled, propor-
tionalrelief valve (PRV1/PRV2),asolenoid valve (SV2),
two logic cartridges (LC1 and LC2), and two brake relief
cartridges (RV8andRV9).Whenthe   PTOswitch isOFF
(or if decks are raised), the deck solenoid valves (SV2
and PRV1/PRV2) are not energized, allowing hydraulic
flow to by--pass the deck motors through the manifold.
When the PTO switch is turned ON with the decks low-
ered, the solenoid valves (SV2 and PRV1/PRV2) ener-
gize, causing  a shift of  the logic cartridges  (LC1 and
LC2) and  allowing hydraulic flow  to the deck motors.
Brake  relief  cartridges  (RV8  and  RV9)  control  the
#
2
#3
Deck
#6 Deck
#7 Deck
(GM4700)
Deck
(GM4700)
CUTTING DECK LOCATIONS
Figure 13
FROM GEAR PUMP (P1)
FROM GEAR PUMP (P2)
GM 4700--D
ALL DECKS LOWERED
PTO SWITCH ON
Figure 14
Page 4 -- 15
Groundsmaster 4500--D/4700--D
Hydraulic System (Rev. A)
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 274 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website