Toro 90743SL Rev G Groundsmaster 580 30581

Electrical System Quick Checks
Battery Test (Open Circuit Test)
Use a multimeter to measure  the voltage between the
battery terminals.
Voltage Measured
Battery Charge Level
Fully charged (100%)
75% charged
12.68
12.45
12.24
12.06
11.89
v (or higher)
Set the multimeter to the DC volts setting.  The battery
should be at a temperature of 60o to 100o F (16o to 38o
v
v
v
v
50% charged
C). The ignition key should be in the OFF position and
all accessories turned off. Connect the positive (+) me-
ter lead to the positive battery post and the negative (--)
meter lead to the negative battery post. Use the table to
the right to determine charge level of the battery.
25% charged
0% charged
NOTE:  This test provides a relative condition of thebat-
tery. Load testing  of the battery will provide  additional
and more accurate information.
Charging System Test
This is a simple test  used to determine if the charging
system is functioning. It will tell you if the charging sys-
tem has an output, but not its capacity.
Acceptable voltage increase:
Initial Battery Voltage
= 12.25 v
= 12.80 v
= +0.55 v
Battery Voltage after 3 Minute Charge
Difference
Use a multimeter set to the DC volts position. Connect
the positive (+) meter  lead to the positive battery  post
and the negative (--) meter lead to the negative battery
post. Leave the multimeter test leads connected to the
battery and record the battery voltage.
NOTE:  Upon starting  the engine, the  battery voltage
will drop and then  should increase once the engine  is
running.
NOTE:  Depending upon  the condition  of  the battery
charge and battery  temperature, the charging  system
voltage will  increase  at different  rates as  the battery
charges.
Start the engine and run at 2700 RPM (high idle). Allow
the battery to charge for at least 3 minutes. Record the
battery voltage.
After allowing the engine to run for at least three (3) min-
utes, battery voltage should be at least 0.5 volts higher
than initial battery voltage (see example in table to the
right).
NOTE:  While engine is running,  if battery voltage ex-
ceeds 16  volts, the  regulator in  the charging  system
should be inspected.
After allowing the engine to run for at least three (3) min-
utes, if  battery voltage does  not increase at  least 0.5
volts, additional testing  of the battery  and/or charging
system should be performed.
Groundsmaster 580--D
Page 8 -- 7
Electrical System (S/N 30101 & Up) (Rev. E)
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 329 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website