Toro 90743SL Rev G Groundsmaster 580 30581

Retrieving Stored Faults
Clearing Fault Memory
Note:
dated software for this function to operate. This required
software was  installed on machines  starting with S/N
The  machine may  require  installation  of up-
Once a fault is repaired, it must be must be cleared from
the ECU memory so any future fault can then be stored.
1.
Turn Ignition switch to OFF.
70001.
Older   machines   can   have  new   software
installed. Contact your Toro Distributor for assistance.
2.
MovethePTOswitchtotheENGAGEDpositionand
hold.
1.
Turn ignition switch to OFF. Unplug loopback con-
nector and connect Diagnostic ACE to the ECU harness
connector.
3.
Cruise Set button.
Depress and  hold Temp  Override  button OR  the
2.
hold.
Move PTO  switch to the  ENGAGED position and
4.
Turn  Ignition  switch  ON  while holding  the  PTO
switch in the ENGAGED position, and keeping the High
Temp Override button or Cruise Set button depressed.
Maintain this condition until the green lamp on the ECU
starts to flash (approximately 2 seconds).
3.
Turn Ignition switch to ON while continuing to hold
the PTO switch in the ENGAGED position until the top
left lighton theDiagnostic ACEcomes on(approximate-
ly 2 seconds).
5.
Release the PTO Switch and button.  Turn Ignition
switch to OFF. Fault memory is now cleared.
4.
5.
Make sure Diagnostic ACE is set to OUTPUTS.
Release the PTO switch.
IMPORTANT: The Diagnostic ACE display must not
be left  connected to the  machine. After  using the
Diagnostic  ACE, disconnect  it  from the  machine
and reconnect loopback connector  to the harness
connector. The machine will not operate without the
loopback connector installed to the harness. Store
Diagnostic ACE in a dry, secure location.
There will be 8 records displayed.  The fault is dis-
played on the  8th record. Each  record will be dis-
played for 10 seconds. Records will repeat until the
Ignition switch is  turned to OFF. The  machine will
not start in this mode.
6.
Observe Diagnostic ACE for the playback of the re-
tained fault in the ECU memory. The problem circuit will
be flashing.
Electrical System (S/N 30101 & Up) (Rev. E)
Page 8 -- 10
Groundsmaster 580--D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 329 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website