Aerate Operation Problems
Condition
Possible Cause
Correction
________________________________________________________________________________________________________________________________________________________
Machine continues to aerate (but
should not) with traction bail in
neutral.
See Safety Interlock System Prob
lems.
________________________________________________________________________________________________________________________________________________________
Machine aerates (but should not)
with with machine raised in trans
port position.
See Safety Interlock System Prob
lems.
________________________________________________________________________________________________________________________________________________________
Machine starts aerating (but
Water pressure switch faulty.
Test switch and replace if faulty.
should not) with inlet water pres
sure of less than 20 to 30 PSI, or
machine does not stop aerating if
inlet water pressure drops to
Water pressure switch wiring faulty.
Check for short in pressure
switch/controller connections and
wiring and repair as necessary.
10
PSI.
Controller faulty.
Replace controller.
________________________________________________________________________________________________________________________________________________________
Machine does not start aerating
when engage button is pushed in
(pump drive belt does NOT ro
tate).
Problem not electrical (see Chap
ter 6 - Water System.)
Loose or broken wire.
Check all connections and wiring
and repair as necessary.
Accumulator charge switch faulty.
Test switch and replace if faulty.
Accumulator high pressure switch
faulty.
Accumulator high pressure
switch faulty.T
Pressure gauge switch faulty.
Pump clutch faulty.
Test switch and replace if faulty.
Test clutch and replace if faulty.
Test relay and replace if faulty.
Test switch and replace if faulty.
Pump relay faulty.
Aerator stop (disengage) switch
faulty.
Wheel position switch faulty.
Make sure switch is installed
properly. Test switch and replace
if faulty.
Aerator start (engage) switch faulty.
Controller faulty.
Test switch and replace if faulty.
Replace controller.
Hydroject 3010
Page 5 - 11
Troubleshooting
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Hydroject 3010 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)