Safety Interlock System Problems (continued)
Condition
Possible Cause
Correction
________________________________________________________________________________________________________________________________________________________
No lights on controller come on
when troubleshooting interlock
system.
Battery is dead or disconnected.
Charge battery. Replace battery if
it will not hold a charge. Clean
and tighten connections.
Circuit breaker open.
Reset circuit breaker. Find cause
for open circuit breaker and cor
rect. Replace circuit breaker if
faulty.
Faulty controller ground.
Ignition key switch faulty.
Check controller ground connec
tion and wiring and repair as nec
essary.
Test ignition switch and replace if
faulty.
Loose or damaged wiring in key
switch/controller circuit.
Check all connections and wiring
and repair as necessary.
Controller faulty.
Replace controller.
________________________________________________________________________________________________________________________________________________________
Green light on controller glows
faintly when only red light should
be on (traction bail out of neutral
and aerate engage switch re
leased).
Normal condition.
Troubleshooting
Page 5 - 14
Hydroject 3010
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Hydroject 3010 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)