Testing
Before Performing Water System Tests
1.
The water aeration system operates under very high
pressures and severe duty cycles. Performance of the
water system will be gradually reduced over a period of
time due to normal wear in the pump, valve and ac-
cumulator. If you perform water system tests to isolate
a possible problem, such as reduced hole depth, it is
recommended that ALL tests be performed in the order
listed even if the apparent problem has been isolated,
such as low accumulator pre-charge pressure. This will
verify that all components are operating properly.
WARNING
High pressure water system components can
cause personal injury if disassembled incor
rectly. Discharge water pressure at bleed
valve before attempting any water system
servicing. Open bleed valve slowly and avoid
contact with high velocity water stream.
Figure 13
1. High pressure bleed valve
2.
With engine OFF, open high pressure bleed valve,
and inspect aeration nozzles. Check for plugged noz-
zles. Verify size and quantity (see Nozzle Service and
Replacement). Nozzles that are too large will causeloss
in pressure andcould cause damage to the accumulator
and other water system components.
NOTE: You can check for plugged nozzles by aerating
over a piece of cardboard, then inspecting cardboard.
Testing
Page 6 - 12
HydroJect 3010
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Hydroject 3010 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)