TEST NO. 1: Accumulator Pre-Charge Pressure (Fig. 14, 15, 16, 17)
Pre-charge pressure is measured and  corrected when
the piston is resting on bottom cap of accumulator (high
pressure bleed  valve  open). By  temporarily installing
Charging   Tool  (TOR4001)   to  top  of  accumulator,
Nitrogen  pressure can  be measured  and  if required,
more Nitrogen can be added.
Obtain a  3000 - 3500  PSI or 6000  PSI Nitrogen  tank
from a local  compressed gas or welding  supply shop.
The charging tool is equipped with a Compressed Gas
Association No. 677 tank connection. These tanks con-
tain enough Nitrogen for 20-30 fills.
NOTE: During operation, working pressure of Nitrogen
in accumulator will  be equal to the operating  pressure
of the water system.
Figure 14
1.
High pressure bleed valve
1.
Park machine  on a  level surface, stop  the engine,
engage the parking brake,  open the hood and discon-
nect the engine spark plug wires.
DANGER
Charged accumulators contain high pressure
nitrogen. Nitrogen is  the only gas to  use for
accumulator charging.  Installing IMPROPER
gases in  an  accumulator can  cause an  EX-
PLOSION  AND  DEATH.  Charging   requires
special  tools  and  precautions.  Charge  ac�
cumulators  in  a  well  ventilated  area.  It  is
recommended    that   the   accumulator    be
checked and charged by an Authorized TORO
Distributor.
Figure 15
1. Protective cover
2. Valve cap
Wear  eye protection.  Keep  hands and  face
away from gas valve.
Slowly open high pressure water bleed valve
before servicing  any component  connected
to high pressure  water system. Opening the
high pressure bleed valve allows any trapped
water  to escape  from  the system  and  also
allows accumulator piston to move to bottom
of accumulatorcylinder. Failureto open bleed
valve  before servicing  high pressure  water
components can cause  personal injury, DIS-
MEMBERMENT OR DEATH.
Charged accumulators cannot be shipped via
air freight.
2.
Slowly open the high  pressure bleed valve allowing
any pressurized water to escape.
3.
Remove protective cover and yellow valve cap from
top side of accumulator.
HydroJect  3010
Page 6 - 13
Testing
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 124 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website