Fuse
The ProForce Debris Blower uses a 15 amp fuse for cir-
cuit protection. The fuse holder for this fuse is located
next to the engine (Fig. 8).
3
The engine wire harness includes a 30 amp fuse for cir-
cuitprotection. Theenginefuseislocatednearthestart-
er motor (Fig. 9).
Testing
1
2
1.
Make sure that ignition switch is OFF.
2.
To prevent unexpected machine operation, discon-
nect the negative battery cable from the battery terminal
(see Battery Service in the Service and Repairs section
of this chapter). Position disconnected negative cable
away from the negative battery terminal.
Figure 8
1.
2.
Wire harness
Fuse
3.
Fuse cover
3.
Press latch that retains fuse holder cover and raise
cover to access fuse.
4.
Withtheuseofamultimeter(ohmssetting),checkfor
2
continuity between fuse terminals by using test ports at
top of fuse. Fuse should have continuity between fuse
terminals.
5.
If necessary, remove and replace fuse.
1
6.
Connect negative battery cable to negative battery
terminal. Tighten nut that secures battery cable from 10
to 15 ft--lb(14 to 20 N--m).Make sure that battery cover
is secured.
Figure 9
1.
Engine fuse
2.
Starter motor
ProForce Debris Blower
Page 4 -- 11
Electrical System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)