Removal (Fig. 20)
Position machine on a firm, level surface. Make sure
engine is  stopped  and remove  key from  the ignition
switch. Chock wheels to prevent machine from moving.
3.  Slide drive pulley onto motor shaft and secure with
flange nut.
1.
4.  Place v--beltinnozzle pulley,route  behind beltguard
(item 13) and install belt on motor pulley.
2.
To prevent unexpected machine operation, discon-
5.  With a 3/8 in. drive  torque wrench, pivot the motor
bracket from 200 to 230 in--lb (23 to 25 N--m) to set v--
belt tension (Fig. 21). Do not over tension belt. Hold
bracket  with the  torque  wrench  and tighten  two  (2)
flange head screws and flange nuts to secure belt ad-
justment and nozzle motor bracket.
nect the negative battery cable from the battery terminal
(see Battery Service in the Service and Repairs section
of this chapter). Position disconnected  negative cable
away from the negative battery terminal.
3.
4.
cures drive pulley to nozzle motor shaft. Loosen flange
nut at least two turns.
Unplug wire harness connector from nozzle motor.
Loosen, but do not fully remove, flange nut that se-
6.
and flange nuts to secure belt guard to machine.
Center belt guard around v--belt.Tighten cap screws
7.  Position leaf  spring with bearing  and flat  washers
(item 5) to bracket. Make sure that five (5) washers are
placed between spring  and bracket at each mounting
hole. The bearing on the leaf spring should be centered
on the outside of the v--belt. Secure leaf spring to motor
bracket with two  (2) cap screws  (item 21) and flange
nuts (item 22).
5.
Removetwo(2)capscrews(item21)andflangenuts
(item 22) that secure leaf spring to motor bracket. Re-
move leaf spring with bearing and flat washers (item 5)
from bracket.
6.
Loosen two  (2) flange head screws  (item 14) and
flange nuts that  secure nozzle motor bracket  to outer
housing. Rotate bracket and nozzle motor to loosen v--
belt.
8.
Connect wire harness to nozzle motor.
9.  Connect negative battery cable to negative  battery
terminal. Tighten nut that secures battery cable from 10
to 15 ft--lb(14 to 20 N--m).Make sure that battery cover
is secured.
7.
Loosen cap screws and flange nuts that secure belt
guard (item  13), route  v--belt from behind  guard and
carefully remove belt from machine.
NOTE:  The shaft of the nozzle motor is tapered.
1
8.
Use appropriate  puller to loosen drive  pulley from
nozzle motor.
9.
tor shaft.
Remove flange nut and drive pulley from nozzle mo-
3
10.Support
nozzle motor to prevent it from falling. Re-
move three (3) cap screws that secure nozzle motor to
bracket. Remove nozzle motor from machine.
3
4
Installation (Fig. 20)
2
1.
Position nozzle  motor to  bracket and  secure with
three (3) cap screws.
Figure 21
1.
2.
Drive pulley
Leaf spring
3.
4.
Flange head screw
Torque wrench access
2.
and drive pulley.
Thoroughly clean  tapered surfaces of  motor shaft
ProForce Debris Blower
Page 4 -- 19
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 83 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website