Removal (Fig. 13)
Position machine on a firm, level surface. Make sure
4
1
1.
engine is  stopped  and remove  key from  the ignition
switch. Chock wheels to prevent machine from moving.
1
1
2
3
2.
To prevent unexpected machine operation, discon-
nect the negative battery cable from the battery terminal
(see Battery Service in the Service and Repairs section
of  Chapter  4 --  Electrical  System).  Position  discon-
nected negative cable away from the negative  battery
terminal.
2
1
5
3
3.
Remove nozzle and nozzle pulley from rear of outer
housing(seeNozzleAssemblyRemovalinthissection).
4.
Remove top grill to allow access to blower assembly
(Fig. 14).
5.
er Drive Shaft Removal in this section).
Remove blower drive shaft from machine (see Blow-
Figure 14
1.
2.
3.
Screw
4.
5.
Top grill
Side grill
6.
moval in this section).
Remove rotor assembly  (see Rotor Assembly Re-
Washer
Flange nut
7.
er housing to fan housing mounts (item 20).
Remove capscrews andflange nuts thatsecure out-
3
4
CAUTION
To prevent  personal injury, make  sure that fan
housing assembly is properly supported as it is
removed  from the  machine. Assembly  weighs
approximately 70 pounds (31.8 kg).
2
8.
blyonworkbench  withfanshaftpointingstraight   up(Fig.
16).
Liftfan housing assembly from machine. Setassem-
1
Figure 15
9.
Place inner housing on two (2) wood planks (2” x 4”
1.
2.
Wood plank
3.
4.
Outer housing
Mounting holes
or equivalent). Then, place 9/16” (14.3 mm) thick sup-
port between planks and outer housing (Fig. 15).  This
process will support  fan housing assembly to prevent
unexpected shifting  of any components during  disas-
sembly.
9/16” support
12.Fully
cure inner housing flanges to  outer housing. Lift inner
housing assembly out of the outer housing.
remove flange head screws (item 14) that se-
13.If
(see Rotor Shaft Removal in this section).
necessary, disassemble inner housing  assembly
10.Loosen,
screws (item 14) that  secure inner housing flanges to
outer housing.
but do  not remove, eight  (8) flange head
Installation (Fig. 13)
11.
Remove flange head screw  (item 12) that secures
1.
semble inner  housing (see Rotor  Shaft Installation in
this section).
If rotor shaft was  removed from inner housing, as-
each stator vane (item 9) to outer housing. Carefully tilt
vane to free vane lugs from inner housing and remove
vane from  assembly. Repeat  for  all twenty  four (24)
vanes. Inspect each vane to make sure that mounting
lugs and screw threads are in good condition. Replace
any vane that shows signs of damage or wear.
ProForce Debris Blower
Page 5 -- 13
Blower Assembly
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 83 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website