Removal (Fig. 13)
Position machine on a firm, level surface. Make sure
4
1
1.
engine is stopped and remove key from the ignition
switch. Chock wheels to prevent machine from moving.
1
1
2
3
2.
To prevent unexpected machine operation, discon-
nect the negative battery cable from the battery terminal
(see Battery Service in the Service and Repairs section
of Chapter 4 -- Electrical System). Position discon-
nected negative cable away from the negative battery
terminal.
2
1
5
3
3.
Remove nozzle and nozzle pulley from rear of outer
housing(seeNozzleAssemblyRemovalinthissection).
4.
Remove top grill to allow access to blower assembly
(Fig. 14).
5.
er Drive Shaft Removal in this section).
Remove blower drive shaft from machine (see Blow-
Figure 14
1.
2.
3.
Screw
4.
5.
Top grill
Side grill
6.
moval in this section).
Remove rotor assembly (see Rotor Assembly Re-
Washer
Flange nut
7.
er housing to fan housing mounts (item 20).
Remove capscrews andflange nuts thatsecure out-
3
4
CAUTION
To prevent personal injury, make sure that fan
housing assembly is properly supported as it is
removed from the machine. Assembly weighs
approximately 70 pounds (31.8 kg).
2
8.
blyonworkbench withfanshaftpointingstraight up(Fig.
16).
Liftfan housing assembly from machine. Setassem-
1
Figure 15
9.
Place inner housing on two (2) wood planks (2” x 4”
1.
2.
Wood plank
3.
4.
Outer housing
Mounting holes
or equivalent). Then, place 9/16” (14.3 mm) thick sup-
port between planks and outer housing (Fig. 15). This
process will support fan housing assembly to prevent
unexpected shifting of any components during disas-
sembly.
9/16” support
12.Fully
cure inner housing flanges to outer housing. Lift inner
housing assembly out of the outer housing.
remove flange head screws (item 14) that se-
13.If
(see Rotor Shaft Removal in this section).
necessary, disassemble inner housing assembly
10.Loosen,
screws (item 14) that secure inner housing flanges to
outer housing.
but do not remove, eight (8) flange head
Installation (Fig. 13)
11.
Remove flange head screw (item 12) that secures
1.
semble inner housing (see Rotor Shaft Installation in
this section).
If rotor shaft was removed from inner housing, as-
each stator vane (item 9) to outer housing. Carefully tilt
vane to free vane lugs from inner housing and remove
vane from assembly. Repeat for all twenty four (24)
vanes. Inspect each vane to make sure that mounting
lugs and screw threads are in good condition. Replace
any vane that shows signs of damage or wear.
ProForce Debris Blower
Page 5 -- 13
Blower Assembly
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)