Toro 04127SL Rev C Service Manual Workman E2050 E2065 Preface Publication

Commutator Service
Chuck  armature on  the  commutator  end–bearing
MICA
1.
COPPER SEGMENT
journal and support the drive end of armature using the
”live” center of the shaft. With the armature supported on
both ends, measure the commutator runout and the bar
to bar differences with a dial gauge. Total indicated run-
out should not exceed 0.003” (0.08 mm) and not more
than 0.0005” (0.013 mm) between any two  bars. If the
readings fall outside this limit, the commutator must be
turned and re–undercut.
.040”
(1.0
mm)
GOOD UNDERCUT
MICA
MICA
COPPER SEGMENT
COPPER SEGMENT
2.
If  the commutator  must be  turned,  use only  high
quality cutting tools  with a controlled  cutting rate. Re-
move only enough copper to bring total indicated runout
and bar to bar height differences into specification.
BAD UNDERCUT
(CUT TOO WIDE)
BAD UNDERCUT
(CUT TOO NARROW)
3.
mm). If the commutator diameter falls below this diame-
ter after turning, the armature must be replaced.
The minimum  commutator  diameter is  2.750” (70
Figure 61
4.
a uniform depth of 0.040” (1.0 mm). Be careful to only cut
the mica and not increase the slot width (Fig. 61).
After the commutator is turned, undercut the mica to
Traction Motor Specifications
BRUSH LENGTH
Maximum
Minimum
1.300 in
0.620 in
33 mm
16 mm
CAUTION
BRUSH SPRING
TENSION
When using compressed air for  cleaning mo-
tor components, follow all safety instructions,
including wearing eye and respiratory protec-
tion.
New Brush
Worn Brush
65 ounces
40 ounces
1820 grams
1120 grams
COMMUTATOR
New Diameter
2.920 in
2.800 in
74 mm
71 mm
5.
After undercutting, use No.  00 sandpaper to lightly
Minimum Diame-
ter for Reslotting
remove any burrs left from the undercutting  operation.
Clean commutator with dry, oil free compressed air and
recheck commutator runout.
Reject Diameter
2.750 in
70 mm
Armature Testing
Before an armature is reassembled into the motor, the
following tests should be performed:
NOTE:  Armature is wave wound and can be short cir-
cuit tested in the following manner.
1.
Check for grounded circuits by placing one test lead
of a dielectric  tester on the commutator and  the other
lead at the armature shaft. If the test light comes on, the
armature is grounded.
2.
growler. Use a long, flat piece of metal (such as a hack-
saw blade) to locate any shorted windings.
Check for short circuits by placing the armature on a
If armature is found  to be shorted, grounded or  other-
wise damaged, replace the traction motor.
Electrical System (Rev. B)
Workman e2050/e2065
Page 3 – 40
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 120 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Product TypeWalk Behind Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website