Aerator Control Module
The ProCore 648 is equipped with an Aerator Control
Module to monitor and control electrical components re•
quired for safe operation. This Module is located on the
inside of the console cover (Fig. 33).
2
Inputs from the start (ignition), head low limit, head high
limit, transport limit #1 proximity switch, aeration #4
proximity switch and ground follow switches are moni•
tored by the Module. The condition (open or closed) of
the ”OK to lower” circuit is also monitored by the Module.
Output to the three hydraulic solenoid valves (lower
SVL, raise SVR and quick raise SVQ) are controlled
based on the inputs received by the Module.
1
The Aerator Control Module does not connect to an ex•
ternal computer or hand held device, can not be re–pro-
grammed and does not record intermittent fault data.
Figure 33
1.
Console cover
2.
Control module
The Aerator Control Module can be used to check op•
eration of machine switches by monitoring the LED’s of
the module. If a module LED does not illuminate (e.g. the
ground follow LED does not illuminate when the ground
follow switch is in the ON position), testing of the switch
and circuit wiring would be required.
8
7
6
9
5
10
Control Module Inputs
The power input LED should be illuminated when the
ignition switch is in the ON position.
The head low input LED should be illuminated when the
head low limit switch is closed.
ProCore 648 Aerator
The head high input LED should be illuminated when the
head high limit switch is closed.
The transport #1 input LED should be illuminated when
the transport limit #1 proximity switch is closed (coring
head raised).
1
4
The aerate #4 input LED should be illuminated when the
aeration #4 proximity switch is closed (coring head low•
ered).
2
3
Figure 34
1.
2.
3.
4.
5.
Power input LED
SVL output LED
SVR output LED
SVQ output LED
Head low input LED
6.
7.
8.
9.
Head high input LED
Transport #1 input LED
Aerate #4 input LED
Ground follow ON LED
The ground follow ON LED should be illuminated when
the ground follow switch is in the ON position.
10. “OK to lower” input LED
The ”OK to lower” input LED should be illuminated when
the ”OK to lower” circuit is closed (see OK to Lower Cir•
cuit in the Circuit Operation section of this chapter).
Electrical System
ProCore 648
Page 5 – 24
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro 648 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone: