Toro 04129SL Rev C ProCore 648 Service Manual

Aerator Control Module
The ProCore 648  is equipped with an Aerator  Control
Module to monitor and control electrical components re•
quired for safe operation. This Module is located on the
inside of the console cover (Fig. 33).
2
Inputs from the start (ignition), head low limit, head high
limit,  transport limit  #1  proximity  switch, aeration  #4
proximity switch and ground follow switches are  moni•
tored by the Module. The condition (open or closed) of
the ”OK to lower” circuit is also monitored by the Module.
Output  to the  three  hydraulic solenoid  valves  (lower
SVL, raise  SVR and  quick raise  SVQ) are  controlled
based on the inputs received by the Module.
1
The Aerator Control Module does not connect to an ex•
ternal computer or hand held device, can not be re–pro-
grammed and does not record intermittent fault data.
Figure 33
1.
Console cover
2.
Control module
The Aerator Control Module can be used  to check op•
eration of machine switches by monitoring the LED’s of
the module. If a module LED does not illuminate (e.g. the
ground follow LED does not illuminate when the ground
follow switch is in the ON position), testing of the switch
and circuit wiring would be required.
8
7
6
9
5
10
Control Module Inputs
The power input  LED should be  illuminated when the
ignition switch is in the ON position.
The head low input LED should be illuminated when the
head low limit switch is closed.
ProCore 648 Aerator
The head high input LED should be illuminated when the
head high limit switch is closed.
The transport #1 input LED should be illuminated when
the transport limit #1 proximity switch is closed (coring
head raised).
1
4
The aerate #4 input LED should be illuminated when the
aeration #4 proximity switch is closed (coring head low•
ered).
2
3
Figure 34
1.
2.
3.
4.
5.
Power input LED
SVL output LED
SVR output LED
SVQ output LED
Head low input LED
6.
7.
8.
9.
Head high input LED
Transport #1 input LED
Aerate #4 input LED
Ground follow ON LED
The ground follow ON LED should be illuminated when
the ground follow switch is in the ON position.
10. “OK to lower” input LED
The ”OK to lower” input LED should be illuminated when
the ”OK to lower” circuit is closed (see OK to Lower Cir•
cuit in the Circuit Operation section of this chapter).
Electrical System
ProCore 648
Page 5 – 24
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 164 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website