Toro 04129SL Rev C ProCore 648 Service Manual

Battery Service
The battery  is the heart of  the electrical system.  With
regular and proper service, battery life can be extended.
Additionally,  battery and  electrical  component failure
can be prevented.
2
1
CAUTION
When working with  batteries, use extreme cau•
tion  to avoid  splashing  or spilling  electrolyte.
Electrolyte can destroy clothing and burn skin or
eyes.  Always wear  safety  goggles and  a  face
shield when working with batteries.
Figure 38
1.
Negative battery cable
2.
Positive battery cable
Battery Specifications
BCI Group Size UI
300
CCA at 0o F (–18o C)
Inspection and Maintenance
Reserve Capacity of 28 minutes at 80oF (27oC)
1.
cracked or leaking.
Check for cracks in battery case. Replace battery if
Dimensions (including terminal posts and handle)
Length
Width
7.7 inches (19.6 cm)
5.2 inches (13.2 cm)
7.2 inches (18.3 cm)
Height
2.
Check battery terminal posts for corrosion. Use wire
brush to clean corrosion from posts.
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80oF (26.7oC)
Discharged: less than 1.240
IMPORTANT: Before  cleaning  the battery,  tape or
block vent holes to the filler caps and make sure the
caps are on tightly.
Removal and Installation (Fig. 38)
1.
After negative  cable is  removed, loosen  and remove
positive (+) cable.
Loosen and remove negative (–) cable from battery.
3.
Check for signs of wetness or leakage on the top of
the battery which might indicate a loose or missing filler
cap,  overcharging, loose  terminal  post or  overfilling.
Also, check battery case for dirt and oil. Clean the bat•
tery with a solution of baking soda and water, then rinse
it with clean water.
2.
hold down rod. Slide hold down rod away from battery.
Remove wing nuts and washers that secure battery
3.
4.
Carefully remove battery from machine.
4.
place the battery if the seal is broken or leaking.
Check that the  cover seal is not  broken away. Re•
Install battery in reverse order  making sure to con•
nect positive (+) cable to battery before connecting neg•
ative (–) cable.
5.
Check the electrolyte level in each cell. If the level is
below the tops of the plates in any cell, fill all cells with
distilled water between the minimum and maximum fill
lines. Charge at 15 to 25 amps for 15 minutes to allow
sufficient mixing of the electrolyte.
NOTE:  Before connecting the negative (ground) cable,
connect a digital multimeter (set to amps) between the
negative battery post and  the negative (ground) cable
connector. The reading should be less than 0.1 amp. If
the reading is 0.1 amp or more, the machine’s electrical
system should be tested and repaired.
5.
After battery cables have been connected to battery,
make sure that speed selector lever does not come with•
in 1 inch (25.4 mm) of either battery cable when moved
through its entire range of motion. Also check that bat•
tery cables do not contact rotating screen on engine.
ProCore 648
Electrical System
Page 5 – 29
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 164 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website