Toro 04129SL Rev C ProCore 648 Service Manual

Testing
2.  If a battery load tester is not available, the battery can
be tested by conducting a hydrometer test of the battery
electrolyte.
1.
To properly test a battery, perform a high–discharge
test using an adjustable  load tester. This is one of  the
most reliable means of testing a battery as it simulates
the cold–cranking test. A commercial battery load tester
is required to perform this test.
IMPORTANT: Make sure the area around the cells is
clean before opening the battery caps.
A.  Measure the specific gravity  of each cell with  a
hydrometer.  Draw  electrolyte   in  and  out  of   the
hydrometer barrel prior to taking a reading to warm–
up the hydrometer. At the  same time take the tem•
perature of the cell.
CAUTION
Follow the manufacturer’s instructions when us•
ing a battery load tester.
B.  Temperature correct each cell reading. For each
10
oF (5.5oC) above 80oF (26.7oC) add 0.004 to the
specific gravity reading. For each  10oF (5.5oC) be•
A.  Check the voltage  across the battery  terminals
prior to testing the battery. If the voltage is less than
low 80oF (26.7oC)  subtract 0.004 from the specific
gravity reading.
12.4
VDC, recharge the battery.
Example: Cell Temperature
Cell Gravity
100
100oF
1.245
oF minus 80oF equals 20oF
oC minus 26.7oC equals 11.0oC)
multiply by 0.004/10oF equals 0.008
oC    multiply by 0.004/5.5oC equals 0.008)
B.  If the battery has been charged, apply a 150 amp
load for 15 seconds to  remove the surface charge.
Use a battery load tester  following the manufactur-
er’s instructions.
(37.7
20o
F
(11
ADD (conversion above)
Correction to 80oF (26.7oC)
C. Make sure battery terminals are free of corrosion.
D. Measure the temperature of the center cell.
0.008
1.253
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cell specific gravity is less than 1.225, charge the bat•
tery. Charge at the recommended rate and time giv•
en in  Charging or  until all cells  specific gravity  is
E.  Connect a battery load tester to the battery termi•
nals following  the manufacturer’s  instructions.
Connect a digital multimeter to the battery terminals.
F.  Apply a test load of one half the Cranking Perfor•
mance (see Battery Specifications) rating of the bat•
tery for 15 seconds.
1.225
or greater with the difference in specific gravity
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
G. Take  a voltage reading at  15 seconds, then re•
move the load.
H. Using  the table  below, determine the  minimum
voltage for the cell temperature reading:
Minimum
Voltage
Battery Electrolyte
Temperature
9.6
9.5
9.4
9.3
9.1
8.9
8.7
8.5
70oF (and up)
21.1oC (and up)
15.6oC
60oF
50oF
40oF
30oF
20oF
10oF
0oF
10.0oC
4.4oC
–1.1oC
–6.7oC
–12.2oC
–17.8oC
I.   If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini•
mum, return the battery to service.
Electrical System
ProCore 648
Page 5 – 30
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 164 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website